8-6-6

 

 

TC/UB

 

 

 

 

 

 

 

 

 

 

 

 

Items/

 

Adjustable

 

Remarks

Data Saved

 

Range

 

 

 

 

 

 

 

 

UB MODE

 

USER

Select the user bits mode.

 

 

 

 

 

 

TIME

USER:Select UB value set in the LCD

 

 

 

 

 

 

DATE

 

section.

 

 

 

 

 

 

EXT

TIME: Select local time (hours, minutes,

 

 

 

 

 

 

TCG

 

seconds).

 

 

 

 

 

 

FRM RATE

DATE: Select local date and time (2 last

 

 

 

 

 

 

 

digits of year, month, date, time).

 

 

 

 

 

 

REGEN

EXT:

 

 

 

 

 

 

Slaved to UB from TC-IN. If reading

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fails, USER value is retained.

 

 

 

 

 

 

 

TCG: TCG value enters UB.

 

 

 

 

 

 

 

FRM RATE:

 

 

 

 

 

 

 

 

Select same camera shoting

 

 

 

 

 

 

 

 

information (frame rate, etc.) with the

 

 

 

 

 

 

 

 

VAUX UB (VITC UB).

 

 

 

 

 

 

 

REGEN:Read out value stored in the card

C

U

F

 

 

 

and record value continuously.

 

 

 

 

 

 

 

VITC UB MODE

USER/EXT

Select the user bits mode for VAUX TC

 

 

 

 

 

 

TIME

(VITC).

 

 

 

 

 

 

DATE

USER/EXT:

 

 

 

 

 

 

TCG

 

If UB MODE is set to EXT, the EXT

 

 

 

 

 

 

FRM RATE

 

value is recorded. If not, USER value

 

 

 

 

 

 

REGEN

 

set by UB is recorded.

 

 

 

 

 

 

TIME: Select local time (hours, minutes,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

seconds).

 

 

 

 

 

 

 

DATE: Select local date and time (2 last

 

 

 

 

 

 

 

 

digits of year, month, date, time).

 

 

 

 

 

 

 

TCG: TCG value enters UB.

 

 

 

 

 

 

 

FRM RATE:

 

 

 

 

 

 

 

 

Select same camera shoting

 

 

 

 

 

 

 

 

information (frame rate, etc.) with the

 

 

 

 

 

 

 

 

VAUX UB (VITC UB).

 

 

 

 

 

 

 

REGEN:Read out value stored in card and

C

U

F

 

 

 

record value continuously.

 

 

 

 

 

 

 

TCG SET HOLD

ON

ON/OFF switching for the feature that

 

 

 

 

 

 

OFF

always starts recording (when the power is

 

 

 

 

 

 

 

turned ON again) the TCG value that was

 

 

 

 

 

 

 

set before the power is turned OFF.

C

U

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIRST REC TC

 

REGEN

For the first recording after the power is

 

 

 

 

 

 

PRESET

turned on, a P2 card is inserted and then

 

 

 

 

 

 

 

switching from this P2 card to another

 

 

 

 

 

 

 

recording-target P2 card is performed,

 

 

 

 

 

 

 

select whether or not to regenerate the time

 

 

 

 

 

 

 

code as the value on the new P2 card.

 

 

 

 

 

 

 

REGEN:For clips recorded on the recording-

 

 

 

 

 

 

 

 

target P2 card, regenerate the time

 

 

 

 

 

 

 

 

code as the time code of the clip that

 

 

 

 

 

 

 

 

has the most recent date and time.

 

 

 

 

 

 

 

PRESET:

 

 

 

 

 

 

 

 

Use the camera-recorder’s internal

 

 

 

 

 

 

 

 

time code.

 

 

 

 

 

 

 

<Note>

 

 

 

 

 

 

 

Set the date and time accurately. For

 

 

 

 

 

 

 

guidance on setting, see [4-5-2 Setting the

C

U

F

 

 

Internal Clock’s Date and Time].

 

 

 

 

 

 

 

 

P.OFF LCD

 

ON

Select whether or not to display the time

DISPLAY

 

OFF

code setting and counter indication on the

 

 

 

 

 

 

 

LCD monitor when the power is turned OFF.

 

 

 

 

 

 

 

ON:

Display setting and indication while

 

 

 

 

 

 

 

 

the power is turned OFF.

 

 

 

 

 

 

 

OFF: Power-down LCD monitor while

 

 

 

 

 

 

 

 

camera power is turned OFF. Setting

 

 

 

 

 

 

 

 

and indication disabled.

C

U

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Items/

Adjustable

Remarks

Data Saved

Range

 

 

 

 

TC OUT

TCG

Select the time code to be output to the time

 

 

 

 

 

TCG/TCR

code output connector.

 

 

 

 

 

 

TCG: Always output time code generator

 

 

 

 

 

 

value.

 

 

 

 

 

 

TCG/TCR:

 

 

 

 

 

 

Display time code generator value in

 

 

 

 

 

 

E-E mode, and time code reader

 

 

 

 

 

 

value in V-V mode.

C

U

F

 

 

 

 

 

 

 

 

 

 

8-6-7

 

 

UMID SET/INFO

 

 

 

 

 

 

 

 

 

 

 

 

Items/

 

Adjustable

Remarks

 

 

Data Saved

 

Range

 

 

 

 

 

 

 

 

 

 

 

 

COUNTRY

 

NO-INFO

Input the user’s country. NO-INFO is

 

 

 

 

 

 

 

 

 

displayed until the input completes.

 

 

 

 

 

 

 

 

 

 

 

C

U

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORGANIZATION

 

NO-INFO

Input the user’s organisation or company

 

 

 

 

 

 

 

 

 

name. NO-INFO is displayed until the input

 

8

 

 

 

 

 

 

completes.

 

C

U

F

 

 

 

 

 

 

 

 

 

 

 

 

 

USER

 

NO-INFO

Input the user name. NO-INFO is displayed

 

 

 

 

 

 

 

 

 

until the input completes.

 

 

 

 

 

 

 

 

 

 

 

C

U

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEVICE NODE

 

 

Indicate the product ID number.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Note>

 

 

 

 

 

Please refer to [4-5-6 Setting the UMID Information] for the UMID information setting.

The ____ in the Adjustable Range column indicates the preset mode.

111