Mounting the Lens
1 Raise the lens clamping lever and remove the mount cap.
Lens Clamping
Lever
Mount Cap
2 To mount the lens, align the indentation at the top center of the lens mount with the center mark of the lens.
Mark
3 Lower the lens clamping lever to clamp the lens.
4 Secure the cable through the cable clamp, and plug it into the LENS connector.
LENS Connector
5 Adjust the lens flange back.
<Notes>
z Please refer to the lens instruction manual for guidance on lens handling.
z When the lens is removed, install the mount cap to protect the device.
Adjusting the Lens Flange Back
If images are not clearly focused at both telephoto and wide- angle positions during zoom operations, adjust the flange back (distance from the lens mounting surface to the image formation surface).
Once adjusted, the flange back does not need to be
<Note>
Please also refer to the lens instruction manual for directions on adjustment and locations of individual lens parts.
1 Mount the lens on the camera.
Make sure you connect the lens cable.
2 Set the lens iris to manual, and fully open the iris.
Approximately 3m
3 Place the flange back adjustment chart about 3 m from the lens and adjust the lighting on the chart to obtain an appropriate video output level.
If the video level is too high, use the filters or the shutter.
4 Loosen the F.f (Flange focus) ring clamping screw.
<Note>
F.b (Flange back) may be indicated on some lenses.
5 Set the zoom ring to the telephoto position, either manually or by electric drive.
6 Aim the lens at the flange back adjustment chart and turn the distance ring to bring the chart into focus.
7 Set the zoom ring to the
While focusing, take care not to move the distance ring.
8 Repeat Steps 5 to 7 until the lens is in focus at both the telephoto and
9 Firmly tighten the F.f ring clamping screw.
68