6. Inspection of the clock, time code, and user bits

1 Set the user’s bit as required.

Please refer to [4-5-1 Setting the User Bits] for the setting procedures.

2 Set the time code.

Please refer to [4-5-3 Setting the Time Code] for the setting procedures.

3 Set the TCG switch to [R-RUN].

4 Press the REC START/STOP button.

Check that the counter display number changes as recording progresses.

5 Press the REC START/STOP button again.

Check that recording stops and the counter display number stops changing.

6 Set the TCG switch to [F-RUN].

Check that the counter display number changes regardless of recording status.

7 Set the DISPLAY switch to [UB].

Each time the HOLD button is pressed, make sure that the displayed value changes in the following sequence: VTCG

DATE  TIME  No display (time zone)  TCG; and also verify that the displayed value is correct.

If DATE, TIME, or time zone is not correct, refer to [4-5-2 Setting the Internal Clock’s Date and Time] for guidance on setting the correct values.

<Note>

Note that date and time data set for DATE, TIME, and time zone is recorded in clips, and affects the playback sequence, etc. at the time of thumbnail manipulations.

7-2 Maintenance

7-2-1 Cleaning Inside the Viewfinder

z Do not use thinner or other solvents to remove dirt from the viewfinder.

z Wipe the lens with a commercially available lens cleaner.

z DO NOT wipe the mirror. If dirt or rubbish is sticking on the mirror, remove it with a commercially available air blower.

7-2-2 Phenomenon Inherent to CCD Cameras

Smears

Smears may appear when shooting an object with very high brightness.

This phenomenon may appear more frequently as the electronic shutter speed increases.

7-2-3 Replacing the Backup Battery

7

 

The camera is shipped from the factory with a backup battery already mounted.

When the battery runs out, the [BACK UP BATT EMPTY] display appears on the viewfinder screen for 3 seconds after the power switch is turned ON.

The internal clock stops operating when the battery runs out. Also, the TCG time code value returns to [00:00:00:00], and the time code backup is disabled. The battery must be replaced.

Please consult your nearest service center for replacement with a new battery (CR2032).

The backup battery is visible when the panel on the LCD monitor side is removed (right side when viewed from the front).

<Note>

Please contact the store where you purchased the camera or an authorised service provider when replacing the battery.

87