Chapter 2 Installing the Access Point

Mounting Overview

Mounting Overview

You can mount the access point on any of the following surfaces:

Horizontal or vertical flat surfaces, such as walls or ceilings

Suspended ceilings (above and below)

Caution The access point, the antennas, and the power source (power injector or power module) are not designed for outdoor use and must be located in an indoor environment.

The access point ships with a detachable mounting plate and the necessary mounting hardware. Because it is detachable, you can use the mounting plate as a template to mark the positions of the mounting holes for your installation. You then install the mounting plate and attach the access point when you are ready.

Refer to Figure 2-3to locate the various mounting holes for the method you intend to use.

Figure 2-3 Mounting Plate

1

Key hole clips

4

Ceiling or wall mounting holes

 

 

 

 

2

Cable access openings

5

Ground connection

 

 

 

 

3

Locking detent

6

Cable tie point

 

 

 

 

Caution Only the fiber-optic power injector (AIR-PWRINJ-FIB) has been tested to UL 2043 for operation in a building’s environmental air space; no other power injectors or power modules have been tested to UL 2043 and they should not be placed in a building’s environmental air space, such as above suspended ceilings.

Cisco Aironet 1240AG Series Access Point Hardware Installation Guide

 

OL-8371-05

2-7

 

 

 

Page 35
Image 35
Cisco Systems 1240AG manual Mounting Overview, Mounting Plate