Chapter 3 Troubleshooting 1240AG Series Autonomous Access Points
Low Power Condition
Configuring the Access Point System Power Settings Using a Browser
You can also use your browser to set the access point System Power Settings.
Note The access point
Note When using the access point browser interface, you should disable your browser
Figure 3-2 shows the system power setting options and indicates the power status of the access point.
Figure 3-2 System Power Settings
Caution If the access point receives power through PoE, the output current of the power sourcing equipment (PSE) cannot exceed 400 mA per port. The power source must comply with IEEE802.3af or IEC60950 for limited power sources.
Table
Table | Access Point System Power Settings and Cisco Switch Commands |
| |
|
|
|
|
|
|
| Cisco Switch |
Power Source |
| Access Point System Power Settings | Power Command |
|
|
| |
AC power module | Configuration changes are not required | power inline never | |
|
|
| |
Cisco switch that supports | Power Settings: | power inline auto | |
Intelligent Power Management1 | Power Negotiation (selected) |
| |
|
|
| |
|
| Power Injector: |
|
|
| Installed on Port with MAC Address (unchecked) |
|
|
|
| |
Cisco switch that does not | Power Settings: | power inline auto | |
support Intelligent Power |
| ||
Management1 |
|
| |
| Power Injector: |
| |
|
|
| |
|
| Installed on Port with MAC Address (unchecked) |
|
|
|
|
|
Cisco Aironet 1240AG Series Access Point Hardware Installation Guide
|
| ||
|
|