18-3
Catalyst2950 Desktop Switch Software Configuration Guide
78-11380-05
Chapter18 Configuring UDLD Configuring UDLD
Configuring UDLD
This section describes how to configure UDLD on your switch. It contai ns t his c on figurati on
information:
Default UDLD Configuration, page 18-3
Enabling UDLD Globally, page 18-4
Enabling UDLD on an Interface, page 18-4
Resetting an Interface Shut Down by UDLD, page 18-5

Default UDLD Configuration

Table18-1 shows the de fault U DLD configur ation.
A UDLD-capable interface also cannot detect a unidirectional link if it is connected to a
UDLD-incapable port of another switch.
Table18-1 Default UDLD Configuration
Feature Default Setting
UDLD global enable state Globally disabled
UDLD per-interface enable state for fiber-optic media Disabled on all Ethernet fiber-optic interfaces
UDLD per-interface enable state for twisted-pair (copper)
media Disabled on all Ethernet 10/100 and 1000BASE-TX
interfaces
UDLD aggressive mode Disabled