Chapter 3 Installing the Cisco ASR 901 Mobile Wireless Router

Mounting the Cisco ASR 901 Router

Figure 3-4 Stripping a Ground Wire

0.5 in. (12.7 mm) ± 0.02 in. (0.5 mm)

Insulation

Wire lead

60528

Step 4 Slide the open end of your ground lug over the exposed area of the ground wire.

Step 5 Using a crimping tool (as specified by the ground lug manufacturer), crimp the ground lug to the ground wire (Figure 3-5).

Figure 3-5 Crimping a Ground Lug onto the Ground Wire

60529

Step 6 Use a Phillips head screwdriver to attach the ground lug and wire assembly to the front of the router with the 2 screws from the accessory kit.

Step 7 Connect the other end of the ground wire to a suitable grounding point at your site.

Power Connection Compliance

Warning Before performing any of the following procedures, ensure that power is removed from the DC circuit. Statement 1003

Warning Use copper conductors only. Statement 1025

Note The installation must comply with the 2002 National Electric Code (NEC) and other applicable codes.

Cisco ASR 901 Series Aggregation Services Router Hardware Installation Guide

 

OL-23778-01

3-7

 

 

 

Page 35
Image 35
Cisco Systems ASR 9014CFD, A9014CFD manual Power Connection Compliance, Stripping a Ground Wire