Chapter 3 Installing the Cisco ASR 901 Mobile Wireless Router

Mounting the Cisco ASR 901 Router

Wiring the DC-Input Power Source

Warning This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than 10 A minimum, 60 VDC. Statement 1005

Complete the following steps to connect the DC power supply to the Cisco ASR 901 router:

Step 1 Switch off the DC power source at the circuit breaker, and place the circuit breaker in the Off position.

Step 2 Locate the 6-pin terminal block (part number 27-2030-01) (Figure 3-6). The terminal block is located in the accessory kit (part number 53-3085-01 for the Cisco ASR 901 router), which is shipped with the router.

Figure 3-6 6-Pin Terminal Block

282346

Step 3 Plug the 6-pin terminal block into the power connector located on the front side of the router.

Step 4 Connect one end of the customer-supplied power cord (16-AWG copper wire) to the site DC power source.

Step 5 Plug the connector on the power supply cord into the 6-pin terminal block that you plugged into the rear of the router in Step 3.

Warning An exposed wire lead from a DC-input power source can conduct harmful levels of electricity. Be sure that no exposed portion of the DC-input power source wire extends from the terminal block plug. Statement 122

Warning When installing this unit, secure all power cabling to avoid disturbing field-wiring connections. Statement 38

Caution DO NOT power on the unit yet.

Cisco ASR 901 Series Aggregation Services Router Hardware Installation Guide

3-8

OL-23778-01

 

 

Page 36
Image 36
Cisco Systems ASR 9014CFD, A9014CFD manual Wiring the DC-Input Power Source, Pin Terminal Block