Chapter 3 Configuring Fibre Channel Interfaces

Guidelines and Limitations

13 68-ef-bd-a8-40-00 to 68-ef-bd-a8-40-04 JAF1450BMBP

Xbar Ports Module-Type

Model

Status

-------- ----------------------------------- ------------------ ----------

1

0

Fabric Module 3

DS-13SLT-FAB3

ok

2

0

Fabric Module 3

DS-13SLT-FAB3

ok

Xbar

Sw

Hw

World-Wide-Name(s) (WWN)

 

---

-------------- ------

--------------------------------------------------

1

NA

0.4

--

 

2

NA

0.4

--

 

Xbar

MAC-Address(es)

Serial-Num

 

----------------------------------------- ----------

1

NA

JAF1451AMHG

2

NA

JAF1451AMHN

* this terminal session

The running configuration is updated when modules are installed. If you save the running configuration to the startup configuration (using the copy running-configstartup-configcommand), during reboot the switch powers up the same set of modules as before the reboot regardless of the sequence in which the modules initialize. You can use the show port index-allocation startup command to display the index allocation the switch uses at startup.

switch#

show port index-allocation startup

 

Startup

module

index distribution:

 

 

------------------------------------------------------

 

 

 

 

 

+

Slot Allowed

 

Alloted indices info

 

range

Total

Index values

--------------

-------

------------------------------

1

-----

34

0-31,80-81

2

-----

32

32-63

 

3

-----

16

64-79

 

(Slot 1 shares 80-81)

4

-----

48

96-127,224-239

SUP

253-255

3

253-255

 

Note The output of the show port index-allocation startup command does not display anything in the Allowed range column because the command extracts the indices from the persistent storage service (PSS) and displaying an allowed range for startup indices is meaningless.

If a module fails to power up, you can use the show module slot recovery-stepscommand to display the reason.

For information on recovering a module powered-down because port indexes are not available, refer to the Cisco MDS 9000 Family Troubleshooting Guide.

Tip Whenever using mixed Generation 1 and Generation 2 modules, power up the Generation 1 modules first. During a reboot of the entire switch, the Generation 1 modules power up first (default behavior).

PortChannel Limitations

PortChannels have the following restrictions:

 

 

Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

 

 

 

 

 

 

OL-29284-01, Release 6.x

 

 

3-21

 

 

 

 

 

Page 99
Image 99