Cisco Systems DSC9148D8G48PK9 manual NPV Mode

Models: DSC9148D8G48PK9

1 236
Download 236 pages 33.59 Kb
Page 200
Image 200

Chapter 7 Configuring N Port Virtualization

Information About N Port Virtualization

NPV Mode

A switch is in NPV mode after a user has enabled NPV and the switch has successfully rebooted. NPV mode applies to an entire switch. All end devices connected to a switch that is in NPV mode must log in as an N port to use this feature (loop-attached devices are not supported). All links from the edge switches (in NPV mode) to the NPV core switches are established as NP ports (not E ports), which are used for typical interswitch links. NPIV is used by the switches in NPV mode to log in to multiple end devices that share a link to the NPV core switch.

Note In-order data delivery is not required in NPV mode because the exchange between two end devices always takes the same uplink to the core from the NPV device. For traffic beyond the NPV device, core switches will enforce in-order delivery if needed and/or configured.

After entering NPV mode, only the following commands are available:

aaaConfigure aaa functions

arp

[no] remove an entry from the ARP cache

banner

Configure

banner message

boot

Configure

boot variables

callhome

Enter the

callhome configuration mode

cli

CLI configuration commands

clock

Configure

time-of-day clock

do

EXEC command

end

Exit from

configure mode

exit

Exit from

configure mode

fcanalyzer

Configure

cisco fabric analyzer

fcrxbbcredit

Enable extended rx b2b credit configuration

fips

Enable/Disable FIPS mode

hw-module

Enable/Disable OBFL information

interface

Select an

interface to configure

ip

Configure

IP features

ipv6

Configure

IPv6 features

line

Configure

a terminal line

logging

Modify message logging facilities

no

Negate a command or set its defaults

npv

Config commands for FC N_port Virtualizer

ntp

NTP Configuration

port-track

Configure

Switch port track config

power

Configure

power supply

poweroff

Poweroff a module in the switch

radius

Configure

RADIUS configuration

radius-server

Configure

RADIUS related parameters

rate-mode

Configure

rate mode oversubscription limit

rmon

Remote Monitoring

role

Configure

roles

snmp-server

Configure

snmp server

ssh

Configure

SSH parameters

switchname

Configure

system's network name

system

System config command

tacacs+

Enable tacacs+

telnet

Enable telnet

username

Configure

user information.

wwn

Set secondary base MAC addr and range for additional WWNs

 

Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

7-4

OL-29284-01, Release 6.x

Page 200
Image 200
Cisco Systems DSC9148D8G48PK9 manual NPV Mode