Chapter 2 Configuring Interfaces

Verifying Interfaces Configuration

LR RX

Delta

60

5

4

1

4

Not enabled

 

 

 

 

 

 

LR TX

Delta

60

5

4

1

4

Not enabled

 

 

 

 

 

 

Timeout Discards

Delta

60

200

4

10

4

Not enabled

 

 

 

 

 

 

Credit Loss Reco

Delta

60

1

4

0

4

Not enabled

 

 

 

 

 

 

TX Credit Not Available

Delta

60

10

4

0

4

Not enabled

------------------------------------------------------------------------------------------

The following default port monitor policy will be active when the switch comes up:

Policy Name

: slowdrain

Admin status

: Not Active

Oper

status

: Not

Active

Port

type

: All

Ports

------------------------------------------------------------------------------------------

----------

Counter

Threshold

Interval Rising Threshold event

Falling Threshold

event Portguard

 

 

 

 

 

 

 

-------

---------

-------- ---------------- -----

------------------

----- --------- ------

 

 

 

 

 

 

Credit Loss Reco

Delta

5

4

4

1

 

4

Not enabled

 

 

 

 

 

 

 

TX Credit Not Available

Delta

1

20

4

10

4

Not enabled

 

 

 

 

 

 

 

------------------------------------------------------------------------------------------

Configuring Average Credit Nonavailable Duration Threshold and Action

When the average credit nonavailable duration exceeds the set threshold, the port can be error-disabled, a trap can be sent with interface details, and a syslog can be generated with interface details. One or more of these actions can also be combined together. These actions can be turned on or off depending on the situation. The port monitor feature provides the command line interface to configure the thresholds and action. The threshold configuration can be a percentage of credit nonavailable duration in an interval.

The thresholds are that the credit nonavailable duration can be 0 percent to 100 percent in multiples of 10, and the interval can be 1 second to 1 hour. The default is 10 percent in 1 second and generates a syslog.

To configure average credit nonavailable duration threshold and action, refer to the “Port Monitor” section on page 2-15.

Note This feature is not supported on 1 RU fabric switches.

Verifying Interfaces Configuration

This section includes the following topics:

Displaying Interface Information, page 2-42

Displaying TL Port Information, page 2-50

Displaying the ALPA Cache Contents, page 2-51

 

 

Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

 

 

 

 

 

 

OL-29284-01, Release 6.x

 

 

2-41

 

 

 

 

 

Page 63
Image 63
Cisco Systems DSC9148D8G48PK9 manual Verifying Interfaces Configuration