46-2
Cisco IE 2000 Switch Software Configuration Guide
OL-25866-01
Chapter 46 Troubleshooting
Information for Troubleshooting
Note If a remote device does not autonegotiate, configure the duplex settings on the two ports to match. The
speed parameter can adjust itself even if the connected port does not autonegotiate.
SFP Module Security and Identification
Cisco small form-factor pluggable (SFP) modules have a serial EEPROM that contains the module serial
number, the vendor name and ID, a unique security code, and cyclic redundancy check (CRC). When an
SFP module is inserted in the switch, the switch software reads the EEPROM to verify the serial number,
vendor name and vendor ID, and recompute the security code and CRC. If the serial number, the vendor
name or vendor ID, the security code, or CRC is invalid, the software generates a security error message
and places the interface in an error-disabled state.
Note The security error message references the GBIC_SECURITY facility. The switch supports SFP modules
and does not support GBIC modules. Although the error message text refers to GBIC interfaces and
modules, the security messages actually refer to the SFP modules and module interfaces. For more
information about error messages, see the system messag e guide for this release.
If you are using a non-Cisco SFP module, remove the SFP module from the switch, and replace it with
a Cisco module. After inserting a Cisco SFP module, use the errdisable recovery cause gbic-invalid
global configuration command to verify the port status, and enter a time interval for recoverin g from the
error-disabled state. After the elapsed interval, the switch brings the interface out of the error-disabled
state and retries the operation. For more information about the errdisable recovery command, see the
command reference for this release.
If the module is identified as a Cisco SFP module, but the system is unable to read vendor-data
information to verify its accuracy, an SFP module error message is generated. In this case, you should
remove and reinsert the SFP module. If it continues to fail, the SFP module might be defective.
Ping
The switch supports IP ping, which you can use to test connectivity to remote hosts. Ping sends an echo
request packet to an address and waits for a reply. Ping returns one of these responses:
Normal response—The normal response (hostname is alive) occurs in 1 to 10 seconds, depending
on network traffic.
Destination does not respond—If the host does not respond, a no-answe r message is returned.
Unknown host—If the host does not exist, an unknown host message is returned.
Destination unreachable—If the default gateway cannot reach the specified network, a
destination-unreachable message is returned.
Network or host unreachable—If there is no entry in the route table for the host or network, a