Cisco Systems MWR 1900 manual Environmental Monitoring Temperature Sensor, System Specifications

Models: MWR 1900

1 48
Download 48 pages 558 b
Page 16
Image 16
Environmental Monitoring Temperature Sensor

Chapter 1 Overview of the Cisco MWR 1900 Router

Environmental Monitoring Temperature Sensor

Environmental Monitoring Temperature Sensor

The MWR 1900 router has a temperature sensor to detect over-temperature conditions inside the chassis. The over-temperature detection trips at 75°C +/- 5%. This condition is reported to the processor as an interrupt and software then takes action on this interrupt to generate the appropriate alarming. If the router reaches a temperature of 90°C, the power supply will cycle to prevent the box from exceeding that temperature in a powered up state.

System Specifications

Table 1-3lists the Cisco MWR 1900 router system specifications.

Table 1-3 Cisco MWR 1900 Router System Specifications

Description

Specification

 

 

Dimensions (H x W x D)

1.72 x 17.5 x 12.5 in. (4.368 x 44.45 x 31.75 cm) 1RU/19.00 Rack

 

Mount

 

 

Weight

12 lb (5.443 kg)

 

 

Console and Auxiliary ports

RJ-45 connector

 

 

Operating Temperature

14 to 131°F (-10 to + 55°C)

 

 

Non-Operational Temperature

-40 to 158°F (-40 to 70°C)

 

 

Operating Humidity

5 to 90% RH (non-condensing

 

 

Operating Altitude

3000m @ 104°F (40°C)

 

 

Operating Vibration

0.41 Grms, 3 to 500 Hz/2 hours per axis

 

 

Non-Operational Vibration

1.12 Grms, 3 to 500 Hz/30 minutes per axis

 

 

Operating Acoustics

< 60 dBa

 

 

Regulatory Compliance

For regulatory compliance and safety information, see the Regulatory Compliance and Safety

Information for the Cisco MWR 1900 Mobile Wireless Edge Router document.

Cisco MWR 1900 Mobile Wireless Edge Router Hardware Installation Guide

1-6

78-13982-02

 

 

Page 16
Image 16
Cisco Systems MWR 1900 manual Environmental Monitoring Temperature Sensor, System Specifications, Regulatory Compliance