Environmental Monitoring Temperature Sensor

Environmental Monitoring Temperature Sensor

The MWR 1900 router has a temperature sensor to detect over-temperature conditions inside the chassis. The over-temperature detection trips at 75°C +/- 5%. This condition is reported to the processor as an interrupt and software then takes action on this interrupt to generate the appropriate alarming. If the router reaches a temperature of 90°C, the power supply will cycle to prevent the box from exceeding that temperature in a powered up state.

System Specifications

Table 1-3lists the Cisco MWR 1900 router system specifications.

Table 1-3 Cisco MWR 1900 Router System Specifications

Description

Specification

 

 

Dimensions (H x W x D)

1.72 x 17.5 x 12.5 in. (4.368 x 44.45 x 31.75 cm) 1RU/19.00 Rack

 

Mount

 

 

Weight

12 lb (5.443 kg)

 

 

Console and Auxiliary ports

RJ-45 connector

 

 

Operating Temperature

14 to 131°F (-10 to + 55°C)

 

 

Non-Operational Temperature

-40 to 158°F (-40 to 70°C)

 

 

Operating Humidity

5 to 90% RH (non-condensing

 

 

Operating Altitude

3000m @ 104°F (40°C)

 

 

Operating Vibration

0.41 Grms, 3 to 500 Hz/2 hours per axis

 

 

Non-Operational Vibration

1.12 Grms, 3 to 500 Hz/30 minutes per axis

 

 

Operating Acoustics

< 60 dBa

 

 

Regulatory Compliance

For regulatory compliance and safety information, see the Regulatory Compliance and Safety

Information for the Cisco MWR 1900 Mobile Wireless Edge Router document.