Grounding the Router

Chapter 3 Installing the Router

Connecting the MWR 1900 Router to a DC-Input Power Supply

18-AWG copper wire for the power cord.

Wire-stripping tool(s) for stripping both 6- and 18-gauge wires.

Grounding the Router

Follow these steps to ground the router to earth ground. Make sure to follow any grounding requirements at your site.

Warning This equipment is intended to be grounded. Ensure that the host is connected to earth ground during normal use.

Warning When installing the unit, the ground connection must always be made first and disconnected last.

Step 1 Remove the ground-lug screw from the rear panel of the router (shown in Figure 1-3). Use a standard Phillips screwdriver or a ratcheting torque screwdriver with a Phillips head.

Step 2 Set the screw aside.

Step 3 If your ground wire is insulated, use a wire-stripping tool to strip the 6-gauge ground wire to 0.5 inch ± 0.02 inch (as shown below)

.

0.50" ± 0.02" 0.50" ± 0.02" Insulation

Insulation

Wire lead

10358

Step 4 Slide the open end of your ground lug over the exposed area of the 6-gauge wire.

Step 5 Using a Panduit crimping tool, crimp the ground lug to the 6-gauge wire (as shown below).

10360

Cisco MWR 1900 Mobile Wireless Edge Router Hardware Installation Guide

3-8

78-13982-02

 

 