Cisco Systems MWR 1900 manual Required Tools and Equipment

Models: MWR 1900

1 48
Download 48 pages 558 b
Page 29
Image 29
Connecting the MWR 1900 Router to a DC-Input Power Supply

Chapter 3 Installing the Router

Connecting the MWR 1900 Router to a DC-Input Power Supply

This section describes the specifications of the Y-cable.

T1/E1 Multiflex VWIC Y-cables should be made with 4 twisted-pair, shielded, 28-gauge cables.

The cable length of each stub (from the RJ-48C connector to the junction point) should not exceed 3 inches (76 mm).

The cable length from junction point to the patch panel is determined by the customer.

MWR 1900

E1/

T1

MWR 1900

E1/

T1

Stubs

Junction point

Patch panel

Y-Cable

65826

All signals that propagate in the same direction must share the same twisted pair. For example, RX TIP and RX RING must form a single twisted pair.

All unused twisted pairs should be cut flush on both ends of the cable. Any unused wire in a twisted pair where one wire is in use should be cut flush at both ends.

Connecting the MWR 1900 Router to a DC-Input Power Supply

This section contains instructions for:

Required Tools and Equipment

Grounding the Router

Wiring the DC-Input Power Source

Powering On the Router

Warning This unit is intended for installation in restricted access areas. A restricted access area is where access can only be gained by service personnel through the use of a special tool, lock and key, or other means of security, and is controlled by the authority responsible for the location.

Required Tools and Equipment

You need the following tools and equipment:

Terminal block connector (Phoenix part number 1754465).

Ratcheting torque screwdriver with a Phillips head that exerts up to 15 pound-force inches (lbf-in) of pressure.

Panduit crimping tool with optional controlled cycle mechanism, model CT-700, CT-720, CT-920, CT-930, CT-920CH, or CT-940CH.

6-gauge copper ground wire (insulated or noninsulated).

Cisco MWR 1900 Mobile Wireless Edge Router Hardware Installation Guide

 

78-13982-02

3-7

 

 

 

Page 29
Image 29
Cisco Systems manual Required Tools and Equipment, Connecting the MWR 1900 Router to a DC-Input Power Supply