Appendix A IPM FAQs and Troubleshooting Tips

Troubleshooting IPM

You can continue using IPM as usual.

If the attempt to reconnect to the server fails, IPM displays the following message:

Reconnection to the server Failed. Please shutdown this client or restart the server.

To recover, you must either shutdown the client and closer your browser window. Incase this condition persist even after restarting the client, you may have to IPM servers.

Q.Why does IPM lock up sometimes when I’m running in a Web browser?

A.IPM might not be locked up. Instead, a message might have popped up in the background, preventing you from interacting with other windows. If you are running IPM in a Web browser, and you suspect your display has locked up, look for an IPM message popup in the background before taking any other action.

This problem also can occur when you launch the Seed File window or the Statistics Data Filter window.

Q.Why won’t IPM let me delete one of my targets?

A.If you try to delete a target and IPM issues an error message such as Could not delete the target, the reason might be one of the following:

The target is being used as a final target by one or more collectors.

The target is being used as an intermediate hop by one or more Path Echo collectors.

See the “Deleting Targets” section on page 4-5for details about how to resolve this problem.

Q.If I see errors in graphs, what are some problems to look for?

A.If you see No Connection or other errors when you display Real Time or Historical graphs, here are some common problems to look for and correct:

Did you create any collectors on inactive PUs?, page A-13

Did you create any collectors when no LUs were available?, page A-14

Did you create any HTTP collectors that require authentication?, page A-14

Did you specify any incorrect target PU names?, page A-14

Did you specify any incorrect IP addresses?, page A-14

Did you specify large mainframe RU sizes?, page A-14

Q.Did you create any collectors on inactive PUs?

A.Collectors that you create on inactive physical units (PUs) accrue no data for Real Time or Historical graphs. The Real Time graph displays “No Connection” for the Last Data Point.

To avoid this problem, make sure the PUs are active before you create collectors on them. To display the status of the PU from the router, use the show sna IOS command or the show dspu IOS command (for downstream PUs).

 

 

User Guide for Internetwork Performance Monitor

 

 

 

 

 

 

 

OL-11291-01

 

 

A-13

 

 

 

 

 