Cisco Systems OL-7861-01 manual Other Alphanumeric LED Messages continued

Models: OL-7861-01

1 88
Download 88 pages 9.76 Kb
Page 62
Image 62
Table 19 Other Alphanumeric LED Messages (continued)

Verifying and Troubleshooting the Installation

Table 19 Other Alphanumeric LED Messages (continued)

LED Display

Meaning

Source

 

 

 

CLOK

Slot clock configuration done.

RP

DONE

 

 

 

 

 

FABL

Loading fabric downloader2 complete.

RP

LOAD

 

 

 

 

 

IOS

Downloading of Cisco IOS software is complete.

RP

LOAD

 

 

 

 

 

BMA

Cisco IOS software BMA error.

RP

ERR

 

 

 

 

 

FIA

Cisco IOS fabric interface ASIC configuration error.

RP

ERR

 

 

 

 

 

CARV

Buffer carving failure.

RP

ERR

 

 

 

 

 

DUMP

Line card requesting a core dump.

RP

REQ

 

 

 

 

 

DUMP

Line card dumping core.

RP

RUN

 

 

 

 

 

DUMP

Line card core dump complete.

RP

DONE

 

 

 

 

 

DIAG

Diagnostic mode.

RP

MODE

 

 

 

 

 

DIAG

Downloading field diagnostics over the MBus.

RP

LOAD

 

 

 

 

 

DIAG

Downloading field diagnostics over the fabric.

RP

F_LD

 

 

 

 

 

DIAG

Launching field diagnostics.

RP

STRT

 

 

 

 

 

DIAG

Cancel field diagnostics.

RP

HALT

 

 

 

 

 

DIAG

Running field diagnostics tests.

RP

TEST

 

 

 

 

 

DIAG

Field diagnostics were completed successfully.

RP

PASS1

 

 

POST

Launching power-on self-test (POST).

RP

STRT

 

 

 

 

 

UNKN

Unknown state.

RP

STAT

 

 

 

 

 

ADMN

Line card is administratively down.

RP

DOWN

 

 

 

 

 

1.This LED sequence only appears in Cisco IOS release 12.0(24)S or later.

2.The fabric downloader loads the Cisco IOS software image onto the line card.

Cisco XR 12000 Series Router Ethernet Line Card Installation

62