C-6
User Guide for Cisco Unified Service Monitor
OL-9351-01
AppendixC Service Monitor Support for SNMP MIBs
System Application MIB Implementation
Scalar Variables
These variables are used to control MIB table size. You cannot update them.
TableC-6 sysApplElmtPastRunTable
MIB Row Entry Description from the MIB
sysApplElmtPastRunInvocID Part of the index for this table. Identifies the invocation of an application of which
this process is a part.
sysApplElmtPastRunIndex Part of the index for this table. A unique value for each process running on the host.
sysApplElmtPastRunInstallID Part of the index for this table. The value of this object is the same value as the
sysApplInstallElmtIndex for the application element of which this entry represents
a running instance.
sysApplElmtPastRunTimeStarted The time the process was started.
sysApplElmtPastRunTimeEnded The time the process was ended.
sysApplElmtPastRunName The full path and filename of the process.
sysApplElmtPastRunParameters The starting parameters for the process.
sysApplElmtPastRunCPU The last known number of hundredths of a second of the total system CPU resources
consumed by this process.
sysApplElmtPastRunMemory The last known total amount of real system memory, measured in kilobytes,
allocated to this process before it terminated.
sysApplElmtPastRunNumFiles The number of regular files that the process currently has open.
sysApplElmtPastRunUser The process owner's login name.
TableC-7 Scalars
MIB Row Entry Description from the MIB Default Value
sysApplPastRunMaxRows Maximum number of entries allowed in the sysApplPastRun table. 2000
sysApplPastRunTableRemItems Counter for entries removed from the sysApplPastRun table after
the maximum number (sysApplPastRunMaxRows) of entries are
exceeded.
20 entries
sysApplPastRunTblTimeLimit Maximum time that an entry in the sysApplPastRun table can exist
before being removed.
86400 seconds
(1 day)
sysApplElemPastRunMaxRows Maximum number of entries allowed in the
sysApplElmtPastRuntable.
2000 entries
sysApplElemPastRunTableRemItems Counter for entries removed from the sysApplElmtPastRun table
after the maximum number (sysApplElemPastRunMaxRows) of
entries are exceeded.
20 entries
SysApplElemPastRunTblTimeLimit Maximum time that an entry in the sysApplElmtPastRunTable can
exist before being removed.
86400 seconds
(1 day)
sysApplAgentPollInterval Minimum interval at which polling to obtain the status of the
managed resources occurs.
60 seconds