Chapter 4 Troubleshooting the System

Managing Cable Modems on the HFC Network

Sample output:

noisy1#show cable spec

 

 

 

 

 

Group

Frequency

Upstream

Weekly Scheduled

Power

Shared

No.

Band

Port

Availability

 

Level

Spectrum

 

(Mhz)

 

From Time:

To Time:

(dBmV)

 

1

10.000- 0.000

 

 

 

1

No

1

11.000- 0.000

 

 

 

1

No

1

12.000- 0.000

 

 

 

1

No

1

13.000- 0.000

 

 

 

1

No

1

14.000- 0.000

 

 

 

1

No

2

10.000-15.000

 

 

 

2

No

2

10.208 [0.40]

Cable3/0 U1

 

 

2

 

3

20.000- 0.000

 

 

 

3

Yes

3

21.000- 0.000

 

 

 

3

Yes

3

22.000- 0.000

 

 

 

3

Yes

3

23.000- 0.000

 

 

 

3

Yes

3

24.000- 0.000

 

 

 

3

Yes

3

0.400 [0.80]

Cable3/0 U2

 

 

3

 

4

20.000-25.000

 

 

 

4

Yes

4

20.800 [1.60]

Cable3/0 U3

 

 

4

 

5

10.000- 0.000

 

 

 

5

No

5

11.000- 0.000

 

 

 

5

No

5

12.000- 0.000

 

 

 

5

No

5

13.000- 0.000

 

Mon 17:06:00

--- --:--:--

5

No

5

14.000- 0.000

 

Mon 17:08:00

--- --:--:--

5

No

5

13.000- 0.000

 

Mon 17:10:00

--- --:--:--

5

No

5

1.600 [3.20]

Cable3/0 U4

 

 

5

 

6

10.000-13.000

 

 

 

6

No

6

13.000-15.000

 

Mon 17:11:00

Mon 17:12:00

6

No

6

10.800 [1.60]

Cable3/0 U5

 

 

0

 

To display information about a specific interface or upstream port, enter the following command:show cable hop cable-if[upstream portnum]. Information lines describe the frequency hop status of an upstream port.

Table 4-13 Show Cable Hop Parameter Descriptions

Field

Description

 

 

Upstream Port

The upstream port for this information line

 

 

Port Status

Show “down” if frequency is unassigned, “admindown” if the port is

 

shutdown, or the center frequency of the channel if the port is up

 

 

Poll Rate

The rate station maintenance polls are generated (msec)

 

 

Missed Poll Count

The number of missing polls

 

 

Min Poll Sample

The number of polls in the sample

 

 

Missed Poll Pcnt

The ratio of missing polls to the number of polls displayed as a percentage

 

 

Hop Thres Pcnt

The level that the missed poll percentage must exceed to trigger a frequency

 

hop expressed as a percentage

 

 

Hop Period

The maximum rate which frequency hopping will occur (seconds)

 

 

Corr FEC Errors

The number of correctable FEC errors on this upstream port

 

 

Uncorr FEC Errors

The number of uncorrectable FEC errors on this upstream port

 

 

Cisco uBR7200 Series Universal Broadband Router Software Configuration Guide

 

78-5897-01

4-13

 

 

 

Page 13
Image 13
Cisco Systems uBR7200 Series manual Sample output, Field Description