4-15
Cisco uBR7200 Series Universal Broadband Router Software Configuration Guide
78-5897-01
Chapter4 Troubleshooting the System Managing Cable Modems on the HFC Network
noisy1#show cable hop
Upstream Port Poll Missed Min Missed Hop Hop Corr Uncorr
Port Status Rate Poll Poll Poll Thres Period FEC FEC
(ms) Count Sample Pcnt Pcnt (sec) Errors Errors
Cable3/0/U0 down 1000 * * * frequency not set * * * 0 0
Cable3/0/U1 admindown 1000 * * * interface is down * * * 0 0
Cable3/0/U2 admindown 1000 * * * interface is down * * * 0 0
Cable3/0/U3 admindown 1000 * * * interface is down * * * 0 0
Cable3/0/U4 admindown 1000 * * * interface is down * * * 0 0
Cable3/0/U5 admindown 1000 * * * interface is down * * * 0 0
Cable4/0/U0 10.800 Mhz 1000 0 0 ----- 100% 300 0 0
Cable6/0/U0 down 1000 * * * frequency not set * * * 0 0
UsingCisco IOS Release 12.0(5)T1 or higher headend images, youcan use the following command to
obtain specific upstream interface information:
show cable hop
cable-if
[upstream <
portnum
>]
Table4-14 Show Cable Hop Parameter Descriptions
Field Description
Upstream Port The upstream port for this information line
Port Status Show “down” if frequency is unassigned, “admindown” if the port is
shutdown, or the center frequency of the channel if the port is up
Poll Rate The rate station maintenance polls are generated (msec)
Missed Poll Count The number of missing polls
Min Poll Sample The number of polls in the sample
Missed Poll Pcnt The ratio of missing polls to the number of polls expressed as a percentage
Hop Thres Pcnt Thelevel thatthe missedpoll percentagemust exceedto trigger afrequency
hop expressed as a percentage
Hop Period The maximum rate which frequency hopping will occur (seconds)
Corr FEC Errors The number of correctable FEC errors on this upstream port
Uncorr FEC Errors The number of uncorrectable FEC errors on this upstream port
Table4-15 Upstream Port Parameter Descriptions
Field Description
Upstream Port The upstream port for this information line
Port Status Show “down” if frequency is unassigned, “admindown” if the port is
shutdown, or the center frequency of the channel if the port is up
Poll Rate The rate station maintenance polls are generated (msec)
Missed Poll Count The number of missing polls
Min Poll Sample The number of polls in the sample
Missed Poll Pcnt The ratio of missing polls to the number of polls expressed as a percentage
Hop Thres Pcnt Thelevel thatthe missedpoll percentagemust exceedto trigger afrequency
hop expressed as a percentage
Hop Period The maximum rate at which frequency hopping will occur (seconds)