Table 4-28 Cable Upstream Freq-adj Averaging Syntax Descriptions

Syntax

Valid Values

n

Specifies the upstream port number.

 

 

averaging

Specifies that a percentage of frequency adjustment packets is

 

required to change the adjustment method from the regular power

 

adjustment method to the noise power adjustment method.

%of frequency adjustment Specifies the percentage of frequency adjustment packets required to switch from the regular power adjustment method to the noise power adjustment method. Valid range is from 10 through 100 percent.

The following example shows how to change the power adjustment method when the frequency adjustment packet count reaches 50 percent:

router(config-if)#cable upstream 0 freq-adj averaging 50

Setting Downstream Test Signals

This feature provides configuration commands that allow you to create downstream test signals. Both Pseudo Random Bit Stream (PRBS) and unmodulated carrier test signals are now supported.

A PRBS test signal is a random data pattern that has been modulated to look like a real data stream. An unmodulated test signal is a continuous sine wave that looks like a carrier wave on the downstream transmission.

See the following required tasks to create PRBS and unmodulated carrier test signals:

Configure Unmodulated Test Signals

Configure PRBS Test Signals

Configure Unmodulated Test Signals

Table 4-29 Instructions to Configure Unmodulated Test Signals

Step

Command

 

Purpose

 

 

 

 

 

 

1.

# router(config-if)#cable downstream if-output

 

Generates an unmodulated continuous-wave signal

 

 

continuous-wave

 

on the downstream channel. The interface is shut

 

 

 

 

down.

 

 

 

 

 

 

 

2.

Router(config-if)#no cable downstream if-output

 

Stops sending test signals.

 

 

 

 

 

 

 

 

 

 

 

Note

Remember to reenable the

 

 

 

 

 

 

interface to resume normal

 

 

 

 

 

 

operations.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 