Operation
Operating Controls and Indicators
Refer to Figure 3.
| Controls or | Function | Position or Indication |
| Indicators | ||
|
|
| |
|
|
|
|
1. | Red stop button | Stops electrical service to blowers, timers, and heat exchanger. | Press to actuate. |
|
|
|
|
2. | Cycle timer control | Determines pressing cyle time. | Rotate knob to desired |
knob |
| setting. | |
|
|
|
|
3. | Steam timer control | Determines the length of sleeve steaming time. Normally set at | Rotate knob to desired |
knob | 5 seconds. | setting. | |
|
|
|
|
4. | Water gun needle | Turns water on and off to water spray gun. | Turn clockwise to turn |
valve |
| water off. Turn | |
|
|
| counterclockwise to turn |
|
|
| water on. |
|
|
|
|
5. | Reset button | Energizes the air power control circuit. Press must be reset if press gauge | With buck in the out |
|
| (item 6) registers 0 psi. | position, press reset |
|
|
| button. |
|
|
|
|
6. | Gauge, reset system | Indicates that air power is on or off to press. | When gauge shows line |
|
|
| pressure, air is reset to |
|
|
| press. When gauge shows |
|
|
| zero pressure, air must be |
|
|
| reset for press to operate. |
|
|
|
|
7. | Right gray buck in | When pressed simultaneously with the left gray buck in button | Press simultaneously |
button | (item 13), moves buck from dressing position to pressing position inside | with left gray buck in | |
|
| cabinet. | button (item 13) to |
|
|
| actuate. |
|
|
|
|
8. | Black vacuum | Turns vacuum off to buck. | Press to actuate. |
release button |
|
| |
|
|
|
|
9. | Emergency Stop | Exhausts entire air system except for air to collar clamp air cylinder. | Press to actuate. Turn in |
button | Stops buck travel and opens press heads or keeps press heads from | direction of arrow on | |
|
| closing. Press will not operate until air circuit is reset. (Applies to | button to reset. Button |
|
| machines produced after 1997.) | will pop up after |
|
|
| approximately 1/8 turn. |
|
|
| |
10. Collar clamp foot | Opens clamping arm on collar clamp (item 16). | Depress foot pedal to | |
pedal |
| open collar clamp. | |
|
|
| Release foot pedal to |
|
|
| close collar clamp. |
|
|
| |
11. Sleeve extender/ | Moves the sleeve extenders out and turns vacuum on to buck. | Depress foot pedal to | |
vacuum foot pedal |
| actuate. | |
|
|
| |
12. Sleeve extender | Retracts sleeve extenders, which brings them in toward the buck. Should | Press to actuate. | |
release button | be actuated before dressing shirt on buck. |
| |
|
|
| |
13. Left gray buck in | When pressed simultaneously with the right gray buck in button | Press simultaneously | |
button | (item 7), moves buck from dressing position to pressing position inside | with right gray buck in | |
|
| cabinet. | button (item 7) to actuate. |
|
|
| |
14. Red head release | Opens the press heads. Buck will automatically return to the dressing | Press to actuate. | |
button | position when heads open. |
| |
|
|
|
|
Table 1 (Continued)
8 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | AJ0975 |