Operation

Operating Controls and Indicators

Refer to Figure 3.

 

Controls or

Function

Position or Indication

 

Indicators

 

 

 

 

 

 

 

1.

Red stop button

Stops electrical service to blowers, timers, and heat exchanger.

Press to actuate.

 

 

 

 

2.

Cycle timer control

Determines pressing cyle time.

Rotate knob to desired

knob

 

setting.

 

 

 

 

3.

Steam timer control

Determines the length of sleeve steaming time. Normally set at

Rotate knob to desired

knob

5 seconds.

setting.

 

 

 

 

4.

Water gun needle

Turns water on and off to water spray gun.

Turn clockwise to turn

valve

 

water off. Turn

 

 

 

counterclockwise to turn

 

 

 

water on.

 

 

 

 

5.

Reset button

Energizes the air power control circuit. Press must be reset if press gauge

With buck in the out

 

 

(item 6) registers 0 psi.

position, press reset

 

 

 

button.

 

 

 

 

6.

Gauge, reset system

Indicates that air power is on or off to press.

When gauge shows line

 

 

 

pressure, air is reset to

 

 

 

press. When gauge shows

 

 

 

zero pressure, air must be

 

 

 

reset for press to operate.

 

 

 

 

7.

Right gray buck in

When pressed simultaneously with the left gray buck in button

Press simultaneously

button

(item 13), moves buck from dressing position to pressing position inside

with left gray buck in

 

 

cabinet.

button (item 13) to

 

 

 

actuate.

 

 

 

 

8.

Black vacuum

Turns vacuum off to buck.

Press to actuate.

release button

 

 

 

 

 

 

9.

Emergency Stop

Exhausts entire air system except for air to collar clamp air cylinder.

Press to actuate. Turn in

button

Stops buck travel and opens press heads or keeps press heads from

direction of arrow on

 

 

closing. Press will not operate until air circuit is reset. (Applies to

button to reset. Button

 

 

machines produced after 1997.)

will pop up after

 

 

 

approximately 1/8 turn.

 

 

 

10. Collar clamp foot

Opens clamping arm on collar clamp (item 16).

Depress foot pedal to

pedal

 

open collar clamp.

 

 

 

Release foot pedal to

 

 

 

close collar clamp.

 

 

 

11. Sleeve extender/

Moves the sleeve extenders out and turns vacuum on to buck.

Depress foot pedal to

vacuum foot pedal

 

actuate.

 

 

 

12. Sleeve extender

Retracts sleeve extenders, which brings them in toward the buck. Should

Press to actuate.

release button

be actuated before dressing shirt on buck.

 

 

 

 

13. Left gray buck in

When pressed simultaneously with the right gray buck in button

Press simultaneously

button

(item 7), moves buck from dressing position to pressing position inside

with right gray buck in

 

 

cabinet.

button (item 7) to actuate.

 

 

 

14. Red head release

Opens the press heads. Buck will automatically return to the dressing

Press to actuate.

button

position when heads open.

 

 

 

 

 

Table 1 (Continued)

8

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

AJ0975