| Operation |
|
| Table 1 (Continued) |
|
|
|
|
|
| Controls or | Function | Position or Indication |
| Indicators | ||
|
|
| |
|
|
|
|
15. | Sleeve extender | Clamp cuffs and extend sleeves outward for high quality finish. | Extend shirt sleeves via |
rods |
| foot pedal (item 11). | |
|
|
| Retract sleeve extender |
|
|
| arms via sleeve extender |
|
|
| button (item 12). |
|
|
|
|
16. | Collar clamp | Holds shirt collar in place on buck (refer to item 10). | Open and close clamp |
|
|
| with foot pedal (item 10). |
|
|
|
|
17. | Safety bars | Exhausts entire air system except air to collar clamp air cylinder. Stops | Press to actuate. |
|
| buck travel, and opens press heads or keeps press heads from closing. |
|
|
| Press will not operate until air circuit is reset. |
|
|
|
|
|
18. | Counter | Registers number of garments pressed. | Works only when timer is |
|
|
| on. |
|
|
|
|
19. | Steam timer | Turns steam timer on and off. | Push to on or off position. |
selector switch |
|
| |
|
|
| |
20. Cycle timer selector | Turns cycle timer on and off. | Push to on or off position. | |
switch |
|
| |
|
|
|
|
21. | Indicator lamp | Indicates electrical service is on or off to blowers, timers, and heat | Illuminates to indicate |
|
| exchanger. | electrical power is |
|
|
| present. |
|
|
|
|
22. | Black start button | If air is reset to press, applies electrical service to blower and timers. If | Press to actuate. |
|
| air is not reset to press, start button will not operate. |
|
|
|
|
|
AJ0975 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 9 |