Cleaning Air Filter

Air filters remove foreign matter and condensate from supply air as it passes through filter. The frequency at which the filter baffle plate and filter element should be cleaned depends upon the amount of condensate and foreign matter in the supply air. The condensate level should not raise above the baffle. That is a sign of a faulty auto-drain which would need to be cleaned, replaced or repaired.

Erratic regulator operations or loss of regulation is almost always due to dirt.

The following steps outline the procedure for cleaning the air filter.

WARNING

To avoid possible serious injury ALWAYS close air supply line shut-off valve AND lock out air service BEFORE:

opening filter drain cock

removing filter bowl

filling oil bowl

W380

1.Close and lock air service shut-off valve.

2.Remove filter bowl. Use a strap wrench if required. Disassemble regulator, making notes as a guide for reassembly.

3.Clean parts with household soap and blow out body with compressed air.

IMPORTANT: DO NOT use cleansing agents such as acetone, benzene, carbon tetrachloride, gasoline, toluene, etc., which are damaging to the plastic sight glass.

4.Reassemble per your notes. Make sure o-ring is in position on the filter bowl. Tighten bowl to filter body. Tighten slightly more than hand tight.

5.Open air service shut-off valve.

Maintenance kits available. Refer to parts manual for numbers.

Maintenance

Cleaning Steam Strainer

Strainer removes foreign matter from steam. The frequency at which the strainer must be cleaned is dependent upon the amount of foreign matter suspended in the steam. It is recommended that the strainer screen be removed and checked for cleanliness after 2 weeks or 80 hours of operation. If little or no foreign matter has collected on the screen, time between inspections can be increased accordingly.

WARNING

To avoid possible serious injury when cleaning or repairing traps or strainers:

Shut off AND lock out ALL steam service to press.

Let heated surfaces cool.

W381

Cleaning Customer-Furnished Steam Traps

Some steam traps are provided with internal steam strainers. These strainers should be cleaned.

All repairable traps should be opened at least once a year to visually check operating mechanisms.

Remove sediment and dirt from trap body. The mechanism may require cleaning by immersing in appropriate cleaning fluid.

NOTE: Check instructions provided with trap or with trap manufacturer for appropriate cleaning fluids.

AJ0975

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

25