Operation
Quality Troubleshooting45
1 |
| 5 |
1 |
| |
|
| |
| 7 | 7 |
|
|
3
3
| 4 |
2 | 6 |
SHIRT QUALITY
CAB263N
Figure 20
Refer to Figure 20.
Trouble |
| Probable Cause | Solution | |
|
|
| ||
Damp patches | 1. Cycle time too short. | Increase Timer. | ||
on sleeve |
|
|
| |
2. | Boiler pressure too low. | Adjust pressure. | ||
(item 1) | ||||
|
|
| ||
| 3. | Faulty trap or check valve in steam return | Clean, repair or replace faulty trap or check valve. | |
| line from condensate tank. |
| ||
|
|
|
| |
| 4. | Steam supply coming from bottom of | Correct inlet piping. Refer to Installation Manual. | |
| header, no riser. |
| ||
|
|
| ||
Placket bowing | 1. Operator pulling shirt too tightly on buck. | Dress shirt so it hangs in natural “A.” Refer to Buck | ||
at the button |
|
| Dressing Instructions. | |
strips (item 2) |
|
|
| |
2. | Shirt not held in place by vacuum. | Fan or draft in plant blows shirt during transfer. | ||
| ||||
|
|
| Redirect fan. Close window or door which causes draft. | |
|
|
| Check for hole or collapsed hoses. Flannel padding is | |
|
|
| too thick. Install thirty ounce (30 oz.) flannel padding. | |
|
|
|
| |
| 3. | Air remains in side air bags at end of | Damper to heat exchanger is not closing off or is not | |
| pressing cycle and distorts shirts. | closing off soon enough. Adjust as necessary. | ||
|
|
|
| |
| 4. | Air to side air bags distorts shirt before | Adjust high pressure air to buck air bags. | |
| heads begin to press. |
| ||
|
|
|
| |
|
| Table 2 (Continued) |
20 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | AJ0975 |