DIP switch 3

No.

 

 

Function

ON

OFF

Factory setting

1

 

Bit length

 

7 bits

8 bits

OFF

 

 

 

 

 

 

 

2

 

Parity

 

Available

Not available

OFF

 

 

 

 

 

 

3

 

Odd /Even

Even number

Odd number

OFF

 

 

 

 

 

 

4

 

Communication mode

XON/XOFF

DTR/DSR

OFF

DIP switch 4

 

 

 

 

 

 

 

 

 

 

 

No.

 

 

Function

ON

OFF

Factory setting

 

 

 

 

 

 

 

1

 

Baud rate

 

See the table below.

OFF

 

 

 

 

 

2

 

Baud rate

 

ON

 

 

 

 

 

 

 

 

 

 

 

3

 

DSR

 

Reset

DSR

OFF

 

 

 

 

 

 

 

4

 

INIT

 

Reset

OFF

 

 

 

 

 

Baud rate (DIP switch 4)

 

 

 

 

 

 

 

 

 

 

 

 

No.

1

2

 

 

Baud rate

 

 

 

 

 

 

 

2400

OFF

OFF

 

 

 

 

 

 

 

 

 

 

4800

ON

OFF

 

 

 

 

 

 

 

 

 

 

9600

OFF

ON

 

 

 

 

 

 

 

 

 

 

19200

ON

ON

 

 

 

 

 

 

 

 

 

Note: Dip switches 3 and 4 are only for serial interface.