8.DRAWER
8.1Specifications of Drawer Kick-Out Connector
8.1.1 Drawer Kick-Out drive signal
A pulse specified by ESC p, DLE DC4 is output. In parallel interface mode, the SW(+) state can be confirmed at No. 34 pin of the interface connector or by the DLE EOT, GS a and GS r commands at the serial/parallel interface.
8.1.2 Electrical characteristics
•Drive voltage: DC 24 V
•Drive current: 0.8 A maximum (Within 510 ms)
• SW signal: Signal level “L” = 0 to 0.5 V “H” = 3 to 5 V
8.1.3 Connector Pin Configuration
No. | Signal | Function |
1 | FG | Frame Ground |
2DRAWER 1 Drawer 1 drive signal
3 | DRSW | Drawer switch input |
4 | VDR | Drawer drive power supply |
|
|
|
5 | DRAWER 2 | Drawer 2 drive signal |
|
|
|
6 | GND | Common ground on circuits |
1 6
Connector used:
Applicable connector:
CAUTION:
•No output is produced while printing.
•The drawers 1 and 2 cannot be driven simultaneously.
•A solenoid used for the drawer should be of 36 Ω or more. The output current should be kept at 0.8 A or less; otherwise, breakdown or burning could occur.
•This connector cannot be connected to a telephone line. Do not connect to anything other than the solenoid.
— 39 —