MRC 7000 Controls Drawing (1 pen)
OFF ON
OFF
HEAT AUTO COOL
BYPASS ACTIVE
MIXER KETTLE OPERATION USING MRC 7000 (1 PEN)
Note: Temperature probe on mixer bridge must be covered with a minimum of three inches of product to function correctly.
1.Turn MAIN POWER switch to "ON".
2.Turn HEAT/COOL switch to "OFF/AUTO".
3.Turn ACTIVE/BYPASS switch to "ACTIVE".
4.Open steam valve completely.
5.On controller keypad push and hold key "" or
"" until desired temperature is set.
6.To start: push scroll key
"" until "CtrL" is displayed.
7.Push down key "".
8.To stop: push scroll key
" " until "OFF " is displayed.
9.Push down key " ".
NOTE: For twin kettles, the MRC 7000 will control the kettle the mixer is in.
OFF
HEAT AUTO COOL
BYPASS ACTIVE
BYPASS ACTIVE
10
If the unit is used continually it may be simpler to control the "ON/OFF " function with the following steps:
1.Keep HEAT/COOL switch at "OFF/AUTO".
2.To stop turn ACTIVE/BYPASS switch to "BYPASS".
3.To change temperature setting push and hold key
"" or " " until desired temperature is set.
4.To start, turn ACTIVE/BYPASS switch to "ACTIVE".