Cleveland Range MKDL-80-CC Piping Schematic, Steam Requirements For Kettles, Steam Pipe Sizing

Models: MKDL-40-CC MKDL-80-CC MKDL-125-CC

1 43
Download 43 pages 20.18 Kb
Page 7
Image 7
PIPING SCHEMATIC

PIPING SCHEMATIC

STEAM IN

DUMP VALVE TO DRAIN

CONDENSATE OUT

COOLING WATER IN

COOLING WATER OUT

HOT WATER

COLD WATER

GLOBE VALVES

UNIONS

STRAINERS

STEAM REQUIREMENTS FOR KETTLES

Kettle Cap.

Kettle

 

25 psi Steam 265°F

40 psi Steam 287°F

 

80 psi Steam 302°F

U.S. Gal.

Dia.

Lbs./Hr.

Hp./Hr.

Lbs./Hr.

Hp./Hr.

Lbs./Hr.

Hp./Hr.

40

26"

 

100

3

 

120

4

 

 

150

4.5

60

29.5"

150

4.5

 

190

5.5

 

230

7.0

80

33"

210

6.0

 

260

7.5

 

300

9.0

100

36"

260

7.5

 

320

9.5

 

390

11.0

125

40"

320

9.5

 

400

11.5

 

470

14.0

150

40"

390

11.0

 

480

14.0

 

570

17.0

pSteam requirements are maximum per hour.

pIf more than one unit is on the same line then add the steam usage for each one to reach a total.

STEAM PIPE SIZING

Required pipe length in feet/meters

Steam Required

200 Ft.

400 Ft.

600 Ft.

Lbs./Kg. per hour

60 Meters

125 Meters

185 Meters

100/45 Kg.

3/4"

1"

1 1/4"

200/91 Kg.

1"

1 1/4"

1 1/2"

300/136 Kg.

1"

1 1/4"

1 1/2"

400/182 Kg.

1"

1 1/2"

1 3/4"

500/227 Kg.

1 1/4"

1 1/2"

1 3/4"

700/318 Kg.

1 1/2"

1 3/4"

2"

900/409 Kg.

1 1/2"

1 3/4"

2"

NOTES:

pPipe size in inches.

pLess than 50 PSI (3.4 BAR) pressure, increase pipe size by 1/4".

p80 to 100 PSI (5.5 to 6.8 BAR), Decrease pipe size by 1/4".

4

Page 7
Image 7
Cleveland Range MKDL-80-CC Piping Schematic, Steam Requirements For Kettles, Steam Pipe Sizing, Kettle Cap, psi Steam 265F