5.4.1.1 Ribbon Shield Removal / Replacement

The ribbon shield prevents ribbon fabric from rubbing on and smearing printed media. It is a consumable. Replace the shield every four to five ribbon replacements or when it is damaged.

12

Lifter

Ring

34

Tabs

Pull the ribbon guide plate tabs toward you. Insert the new shield tips into the gap between the ribbon guide plate and the carriage

Rotate the shield until it is centered on the carriage. Do not let the shield tips slip behind the carriage.

56

Push the shield up until it stops. Install the ribbon cartridge and lower the carriage.

31

Page 36
Image 36
Craden Peripherals DP8 technical manual Ribbon Shield Removal / Replacement