MIDI Program Change Commands

The Xboard has the ability to transmit a different MIDI Program Change command on each of the 16 MIDI channels. This feature can only be programmed using the Xboard Control software.

MIDI Bank Select Commands

The Xboard also transmits MIDI bank select commands using MIDI continuous controller numbers. Continuous Controller (CC) 0 is the MSB (most significant byte) and CC 32 is the LSB (least significant byte). Normally you send both the MSB and LSB controllers to implement a bank change.

The selected bank remains selected until you change it (either via MIDI or by changing the bank from the display). Standard MIDI Program Change commands select from 128 presets within the selected bank.

Footpedal Wiring

The potentiometer value can be anywhere from 10K ohms to 250K ohms in value. Pedals with these specifications are available at any music dealer.

Footpedal

Wiring

Ring

Sleeve Tip

10K - 250K

Tip

 

 

Sleeve

Ring

Xboard