IQ-USM 810 Service Manual

Procedure:

Set the clock to the current time with the clock write command.

Send: DA DT CT 80 03 09 CK4 CK3 CK2 CK1 CS; Set real time clock

Where CK1, CK2, CK3, and CK4 are the four bytes of the time code.

5.16.2.Allow the IQ-USM810 to operate for > 100 sec-

onds.

Note: other tests may be performed during this time.

Remove TP7-TP8 jumper if in use. Perform a power cycle on the IQ-USM810.

Note; this may be the same power cycle used for the IQ Bus Dropout Relay Operation test.

Read the clock and compare its time with the current time.

Send: DA DT CT 80 03 0A CS

Return String: DA DT AK CT 80 03 0C CK4 CK3 CK2 CK1 CS

Where CK1, CK2, CK3, and CK4 are the four bytes of the time code.

The two times must be within one second.

4.6.16 IQ BUS MASTER CONTROL

Spec: Hardware can force the IQ Bus high. (Open the loop)

For this test, perform IQ communication via the Crown bus.

Procedure:

Send the Master IQ Bus command:

Send: DA DT CT C0 05 09 01 CS; Master IQ bus (Open loop)

Verify no echo responses on subsequent IQ commands: Suggested test string: 01 02 03 04 FE FF

Send the normal IQ Bus command…

Send: DA DT CT C0 05 09 00 CS; Unmaster IQ bus (Close loop)

Verify echo responses on subsequent IQ commands: Suggested test string: 01 02 03 04 FE FF

Return string: 01 02 03 04

4.6.17 IQ BUS DROPOUT RELAY OPERATION

Spec: IQ Bus remains connected when power is re- moved.

For this test, perform IQ communication via the Crown bus.

Procedure:

Power down IQ-USM 810.

130447-1 Rev. A

Verify IQ messages pass through the unit under test: Suggested test string: 01 02 03 04 FE FF

Return string: 01 02 03 04 Reapply power to IQ-USM 810.

4.6.18 IQ BUS HUB / DAISY CONNECTIONS

Spec: Both types on IQ Bus connections are functional.

Note: This product has two types of IQ bus connections. The Daisy type connects the input in one port of the dual RJ-45 and the output in the other. The Hub type connects both input and output to one RJ-45 port.

For this test, perform IQ communication via the Crown bus.

Procedure:

For each type of bus connection (Daisy, Hub), perform at least one of the above tests that require a test on the IQ response.

4.6.19 SHIPPING STATE RESTORATION

Spec: The IQ-USM 810 is returned to the factory de- faults.

Note: This section may be skipped when testing a service unit if it is known that the customer wishes to retain the mixers settings and presets.

Note: The following steps must be performed as part of the final power down sequences to ensure the IQ-USM 810 has been returned to factory defaults and presets. If the IQ-USM 810 is re-powered before packing, the following procedure should be repeated.

Procedure:

Send the select preset 0 command:

Send: DA DT CT B2 7F 09 00 CS; Select preset 0 Send the load preset command:

Send: DA DT CT B4 7F 09 01 CS; Load preset

Note: The load preset command must be sent within approxi- mately 2 seconds of the select preset command.

Send the select preset 32 command:

Send: DA DT CT B2 7F 09 20 CS; Select preset 32 Send the load preset command:

Send: DA DT CT B4 7F 09 01 CS; Load preset

Note: The load preset command must be sent within approxi- mately 2 seconds of the select preset command.

Note: Preset 0 and 32 may also be selected using the front panel controls.

1)Use the “” and “” keys to select preset 0. (Display shows P00.)

2)Press “SEL” switch.

3)Use the “” and “” keys to select preset 32. (Dis- play shows P32.)

4)Press “SEL” switch.

4-6 Maintenance

©2000 Crown International, Inc.

Page 26
Image 26
Crown Audio IQ-USM 810 service manual IQ BUS Master Control