CY14B104L, CY14B104N

Software Controlled STORE/RECALL Cycle

In the following table, the software controlled STORE/RECALL cycle parameters are listed.[25, 26]

Parameters

Description

 

20 ns

 

25 ns

 

45 ns

Unit

Min

Max

Min

Max

Min

Max

 

 

 

tRC

STORE/RECALL Initiation Cycle Time

20

 

25

 

45

 

ns

tSA

Address Setup Time

0

 

0

 

0

 

ns

tCW

Clock Pulse Width

15

 

20

 

30

 

ns

tHA

Address Hold Time

0

 

0

 

0

 

ns

tRECALL

RECALL Duration

 

200

 

200

 

200

μs

tSS [27, 28]

Soft Sequence Processing Time

 

100

 

100

 

100

μs

Switching Waveforms

Figure 12. CE and OE Controlled Software STORE/RECALL Cycle[26]

 

W5&

W5&

 

$GGUHVV

$GGUHVV

$GGUHVV

 

W6$

W&:

W+$

 

W

 

 

 

&:

 

&(

W+$

W66

 

W6$

 

W+$

 

W+$

 

 

 

2(

 

 

 

 

 

W'(/$<

W+++'

+6% 6725(RQO\

W+=&(

 

 

W/=&(

 

 

W/=+6%

'4 '$7$

 

 

+LJK

 

 

,PSHGDQFH

 

 

 

 

 

W6725(

W5(&$//

5:,

 

 

 

Figure 13. Autostore Enable / Disable Cycle

 

W5&

W5&

$GGUHVV

$GGUHVV

$GGUHVV

W6$

W&:

W&:

 

&(

W+$

W+$

W6$

W+$

 

W

 

 

+$

2(

 

 

 

W+=&(

W66

W/=&(

W

 

 

'(/$<

'4 '$7$

 

 

5:,

 

 

Notes

25.The software sequence is clocked with CE controlled or OE controlled reads.

26.The six consecutive addresses must be read in the order listed in Table 1 on page 5. WE must be HIGH during all six consecutive cycles. After the sixth address read cycle, no further read or write operation must be performed for tSS duration. If these conditions are not met, the software sequence is aborted.

Document #: 001-07102 Rev. *L

Page 13 of 25

[+] Feedback

Page 13
Image 13
Cypress CY14B104N, CY14B104L Software Controlled STORE/RECALL Cycle, Parameters Description 20 ns 25 ns 45 ns Unit Min Max