Air Conditioner Operating Instructions (cont’d)

5)Press the FAN key to select the desired fan speed setting (Low-Med-High). See Fig. 14. Your selection will be displayed in the LCD window (each depression of the fan key will advance to a different setting).

6)Press the SWING key to activate the automatic air swing (oscillating) feature (the “air swing” symbol will appear in the LCD window). Fig. 15. To deactivate the air swing feature, press the SWING key again.

TIMER

ON

12:00

I/O

MODE

 

 

 

TEMP./CLOCK

MODE

COOL

 

 

 

ADJ.

 

FAN

ON

 

FAN SPEED HIGH

 

 

 

 

TIMER

 

 

 

00

 

 

 

TEMP.

SWING

OFF

CLOCK

 

 

 

Fan Speed

Fig. 14

7)

Condensed water will be accumulated in the

 

water tank. When the tank is full, the unit will

 

sound a signal (8 beeps) and the Water Full

 

indicator light start flashing. At this time the air

 

conditioning process will immediately stop.

 

However, the fan motor will continue to operate

 

(this is normal). Carefully remove the water tank

 

from the cabinet and dispose of the water.

 

Replace the water tank back to it’s original

 

position (in cabinet) and the air conditioning

 

process will automatically resume. It may take

 

3-5 minutes for the compressor to re-start. This

 

is normal.

8)

To adjust “air flow” direction, (up / down only)

 

adjust any one of the Horizontal Louver Blades

 

(excluding the top or bottom louver) and the

 

remaining louvers will automatically adjust to the

 

set position (excluding the top and/or bottom

TIMER

ON

 

12:00

I/O

MODE

 

 

 

 

TEMP./CLOCK

MODE

COOL

 

 

 

ADJ.

 

FAN

ON

 

FAN SPEED

HIGH

 

 

 

 

TIMER

 

 

 

 

00

 

 

SWING

 

TEMP.

SWING

OFF

CLOCK

 

 

 

 

Air Swing

 

 

 

 

Fig. 15

 

 

 

 

 

 

louvers). Fig. 16.

Cooling stops automatically when the set temperature is achieved. Cooling resumes when the room temperature rises above the set temperature level. The temperature has no effect on the fan operation. Therefore, the fan will operate continuously (after the compressor has cycled off) to maintain optimal temperature control.

CAUTION

During air conditioning and dehumidifying modes, if the compressor cycle is interupted (unplugged, power failure,etc.) and reinstated immediately thereafter, (within 3-5 minutes) a “compressor protection circuit” is automatically self-affected. The mode indicator light will flash “green” for approximately 10 seconds, confirming the protection circuit is activated. The compressor cannot operate during a “compressor protecton” condition. (this is normal) It may take 3-5 minutes before the “protection circuit” self-deactivates.

DO NOT ATTEMPT TO START THE UNIT (COMPRESSOR) DURING THIS PERIOD. Upon re-starting the unit (turn 1/0 switch on) all program information(i.e. time, mode, fan speed, auto timed programs) will have to be re-set.

10

Fig. 16

ATTENTION

Removal and/or partial displacement of the water tank will cause the compressor to stop operating (this is a safety feature). This condition will cause the unit to “beep 8 times” and the “water full” light will flash (red) continuously until corrected. The compressor cannot operate during a flashing “red” light condition. Check the following;

1.Is the water tank full?

Empty and re-install water tank.

2.Has the water tank been accidently displaced? Re-position water tank.

The “red” light will stop flashing automatically when the water tank has been emptied and/or correctly re-positioned.

Page 22
Image 22
Danby SPAC8499 manual Air Conditioner Operating Instructions cont’d, Excluding the top or bottom louver, Louvers. Fig