Electrical Specifications

Electrical Specifications

1.All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.

2.Check available power supply and resolve any wiring problems BEFORE installation and operation of this unit.

3.This unit draws 9.0 amps (nameplate rated) under Cooling Mode and 12.0 amps (nameplate rated) under Heating Mode and may be used in any properly wired, general purpose 15 amp household grounded receptacle.

4.For your safety and protection, this unit is grounded through the power cord plug when plugged into a matching wall outlet. If you are not sure whether the wall outlets in your home are properly grounded, please consult a qualified electrician. DO NOT USE PLUG ADAPTERS

OR EXTENSION CORDS WITH THIS UNIT. If it is necessary to use an extension cord with this unit, use an approved “air conditioner” extension cord only. (available at most local hardware stores)

5.The manufacturers nameplate is located on the rear panel of the unit and contains electrical and other technical data specific to this unit.

6.To avoid the possibility of personal injury, always disconnect the power supply to the unit, before installing and/or servicing.

Table 1

Suggested Individual Branch Circuit

Nameplate Amps

AWG Wire Size*

7.4 to 12.0

14

AWG- American Wire Gage

* Based on copper wire at 60°C temperature rating.

 

Table 2

 

 

 

 

 

Receptacle and Fuse Types

 

 

 

 

 

 

Rated Volts

125

 

Amps

15

 

 

 

 

 

 

 

 

Wall Outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuse Size

15

 

 

 

 

 

 

 

 

Time Delay Fuse

Plug Type

(or circuit breaker)

 

 

 

 

 

 

 

 

 

 

 

Unit Specifications:

Model SPAC8499

 

 

Cooling Capacity

8400 Btu/h

Heating Capacity (High/Low)

1380W/830W

Dehumidifying Capacity

57 Pints (27 L / 24 Hrs)

Noise Level

Less than 54 dB(A)

Power Source

115 V / 60 Hz

Refrigerant

R22

Internal Water Tank Capacity

5.5 L (11.6 Pints)

External Water Tank Capacity

8.5 L (18 Pints)

Unit Weight

38 kg (83.7 lb.)

Unit Dimensions (inches) W x D x H

15 1/4" x 18" x 32 5/8"

Unit Dimensions (cm) W x D x H

38.7 x 45.6 x 82.9

Fan Speeds

3

Control Panel (Illuminated)

Soft Touch Controls

Remote Control

Yes

Time of Day Clock

Yes

Auto - Timer

Yes

 

 

Power Consumption:

 

 

 

Cooling

1050 Watts (9.0 Amps)

Heating

1380 Watts (High) 12 Amps

 

830 Watts (Low) 7.2 Amps

Dehumidifying

1050 W (9.0 Amps)

Fan

90 W (0.8 Amps)

 

 

NOTE: Specifications are subject to change without notice, for further improvements.