RAPID CONFIGURATION 
 9
1
STEP 6 – X-PRESS™ CONFIGURATION Once Matrix 400™ has calibrated image density, you can configure it for optimal code 
reading relative to your application. This configuration can be performed either through the X-
PRESS™ Interface or the VisiSet™ configuration program. 
1. Enter the Focus function by pressing and holding 
the X-PRESS™ push button until the Focus LED 
is on. 
2. Release the button to enter the Focus function. 
The Blue Diamonds™ turn on. 
3. Select a code from your application. Position 
the code at the center of the FOV (equidistant from 
the Blue Diamonds™). 
4. Exit the Focus function by pressing the X-
PRESS™ push button once. The Blue 
Diamonds™ turn off. 
READY 
g
reen 
g
reen 
y
ellow 
y
ellow 
red 
SETUP
FOCUS
T
ES
T
LEARN
GOOD 
T
RIGGER 
COM 
STATUS 
Figure 12 – X-PRESS™ Interface: 
Locate Function 
5. Enter the Setup function by pressing and holding 
the X-PRESS™ push button until the Setup LED is 
on. 
6. Release the button to enter the Setup function. 
The Setup LED will blink until the procedure is 
completed. 
The Setup procedure ends when the Image 
Acquisition parameters are successfully saved in 
the reader memory, the Setup LED will remain on 
continuously and Matrix 400™ emits 3 high pitched 
beeps. 
If the calibration cannot be reached after a timeout 
of about 5 (five) seconds Matrix 400™ will exit 
without saving the parameters to memory, the 
Setup LED will not remain on continuously but it will 
just stop blinking. In this case Matrix 400™ emits a 
long low pitched beep. 
7. Exit the Setup function by pressing the X-
PRESS™ push button once. 
READY 
green 
green 
y
ellow 
y
ellow 
red 
SETUP
FOCUS
T
ES
T
LEARN
GOOD 
T
RIGGER 
COM 
STATUS 
Figure 13 – X-PRESS™ Interface: 
Setup Function