RAPID CONFIGURATION
9
1
STEP 6 – X-PRESS™ CONFIGURATION
Once Matrix 400™ has calibrated image density, you can configure it for optimal code
reading relative to your application. This configuration can be performed either through the X-
PRESS™ Interface or the VisiSet™ configuration program.
Locate
1. Enter the Focus function by pressing and holding
the X-PRESS™ push button until the Focus LED
is on.
2. Release the button to enter the Focus function.
The Blue Diamonds™ turn on.
3. Select a code from your application. Position
the code at the center of the FOV (equidistant from
the Blue Diamonds™).
4. Exit the Focus function by pressing the X-
PRESS™ push button once. The Blue
Diamonds™ turn off.
READY
g
reen
g
reen
y
ellow
y
ellow
red
SETUP
FOCUS
T
ES
T
LEARN
GOOD
T
RIGGER
COM
STATUS
Figure 12 – X-PRESS™ Interface:
Locate Function
Setup
5. Enter the Setup function by pressing and holding
the X-PRESS™ push button until the Setup LED is
on.
6. Release the button to enter the Setup function.
The Setup LED will blink until the procedure is
completed.
The Setup procedure ends when the Image
Acquisition parameters are successfully saved in
the reader memory, the Setup LED will remain on
continuously and Matrix 400™ emits 3 high pitched
beeps.
If the calibration cannot be reached after a timeout
of about 5 (five) seconds Matrix 400™ will exit
without saving the parameters to memory, the
Setup LED will not remain on continuously but it will
just stop blinking. In this case Matrix 400™ emits a
long low pitched beep.
7. Exit the Setup function by pressing the X-
PRESS™ push button once.
READY
green
green
y
ellow
y
ellow
red
SETUP
FOCUS
T
ES
T
LEARN
GOOD
T
RIGGER
COM
STATUS
Figure 13 – X-PRESS™ Interface:
Setup Function