MATRIX 400™ REFERENCE MANUAL 
48   
4 
4.2.3  RS485 Half-Duplex Interface NOTE 
This interface is provided for backward compatibility. We recommend using 
the more efficient ID-NET™ network for Master/Slave or Multiplexer layouts. 
The RS485 half-duplex (3 wires + shield) interface is used for polled communication 
protocols. 
It can be used for Multidrop connections with a Datalogic Multiplexer, (see par. 6.5) exploiting 
a proprietary protocol based on polled mode called MUX32 protocol, where a master device 
polls slave devices to collect data. 
CBX100/500 Function 
RTX+  RS485 Receive/Transmit Data + 
RTX-  RS485 Receive/Transmit Data - 
SGND Signal Ground 
 RTX485+ 
SGND RTX485- 
USER INTERFACE
SGND RTX+ 
RTX- 
READER 
Figure 54 - RS485 Half-duplex Connections 
This interface is forced by software when the protocol selected is MUX32 protocol. 
In a Multiplexer layout, the Multidrop address must also be set via serial channel by the 
VisiSet™ utility or by the Host Programming Mode. 
Figure 55 shows a multidrop configuration with Matrix 400™ readers connected to a 
Multiplexer. 
CAUTION 
This is an example of multidrop wiring. Consult the multiplexer manual for 
complete wiring instructions.