19-PIN CONNECTOR ELECTRICAL CONNECTIONS 
 67
5
5.4.3  RS485 Half-Duplex Interface NOTE 
This interface is provided for backward compatibility. We recommend using 
the more efficient ID-NETâ„¢ network for Master/Slave or Multiplexer layouts. 
The RS485 half-duplex (3 wires + shield) interface is available for polled communication 
protocols. 
It can be used for Multidrop connections with a Datalogic Multiplexer, (see par. 6.5) exploiting 
a proprietary protocol based on polled mode called MUX32 protocol, where a master device 
polls slave devices to collect data. 
The following pins of the M16 19-pin connector are used for RS485 half-duplex 
communication: 
Pin Name  Function 
M  RTX+  RS485 Receive/Transmit Data (+) 
N  RTX-  RS485 Receive/Transmit Data (-) 
L GND  Ground 
 MATRI
X
RTX-
RTX+
MULITPLEXER 
RTX485- 
RTX485+
GND RS485REF 
SHIELD
N
M
L
K
Earth Ground Earth Ground 
Chassis
Figure 80 - RS485 Half-duplex Connections 
This interface is forced by software when the protocol selected is MUX32 protocol. 
In a Multiplexer layout, the Multidrop address must also be set via serial channel by the 
VisiSetâ„¢ utility or by the Host Programming Mode.