19-PIN CONNECTOR ELECTRICAL CONNECTIONS 
 63
5
5  MATRIX 400™ CONNECTOR ELECTRICAL CONNECTIONS 5.1 M16 19-PIN CONNECTOR
The Matrix 400™ reader is equipped with an M16 19-pin male connector (Binder, 423 
Series) for connection to the power supply, serial interfaces and input/output signals. The 
details of the connector pins are indicated in the following table: 
Figure 73 – M16 19-pin Male Connector 
19-pin M16 male connector pinout 
Pin Name  Function 
A  Vdc  Power supply input voltage + 
L  GND  Power supply input voltage - 
K CHASSIS 
Cable shield internally connected by capacitor to the 
chassis 
B  I1A  External Trigger A (polarity insensitive) 
C  I1B  External Trigger B (polarity insensitive) 
D  I2A  Input 2 A (polarity insensitive) 
E  I2B  Input 2 B (polarity insensitive) 
H  O1+  Output 1 + 
F  O1-  Output 1 - 
G  O2+  Output 2 + 
I  O2-  Output 2 - 
S  RX  Auxiliary RS232 RX 
O  TX  Auxiliary RS232 TX 
R ID+  ID-NET™ network + 
P ID-  ID-NET ™ network - 
Pin Name RS232 RS485 
Full-Duplex 
RS485 
Half-Duplex 
M TX TX+ RTX+ 
U RX *RX+  
N RTS TX- RTX- 
T 
MAIN 
INTERFACE 
(SW 
SELECTABLE) CTS  *RX-  
* Do not leave floating, see par. 5.4.2 for connection details. 
In order to meet EMC requirements: 
 connect the reader chassis to the plant earth ground by means of a flat copper braid 
shorter than 100 mm; 
 connect the main interface cable shield to pin K of the 19-pin connector;