CBX ELECTRICAL CONNECTIONS 
 61
4
4.7  EXTERNAL LIGHTING SYSTEMS If an External Illuminator is used, it can be powered from the CBX connection box. It must be 
connected to the Vdc and GND terminal clamps. 
CAUTION 
Power is available directly to the Illuminator, independently from the Power 
Supply Switch inside the CBX. 
In the case of the LT-100, LT-200 or LT-300 illuminators, one of the available digital outputs 
must be connected as the control signal. In VisiSetâ„¢, configure the Output Line Function 
parameter to "External Lighting System" and the Matrix Output x External Lighting System 
Mode parameter to "Triggered". 
 Control Signal for 
LT-100, LT-200 or 
LT-300 illuminators 
Power to External 
Illuminator   
Figure 72 – External Lighting System Connections 
Below is a table summarizing the various External Illuminator wiring and power requirements: 
Illuminator  Wire Color  CBX/Matrix Signal  Meaning 
LT-100  Red  Vdc  10 to 30 Vdc 
LT-200 Black  GND  Ground 
  Blue  O1- or O2-  Control Signal - 
  White  O1+ or O2+  Control Signal + 
LT-300  Brown  Vdc  10 to 30 Vdc 
 Black GND  Ground 
 Yellow/Green Earth  Shield/Earth Ground 
  Blue  O1- or O2-  Control Signal - 
  White  O1+ or O2+  Control Signal + 
LT-210, LT-314,   White  Vdc  24 Vdc 
LT-316, LT-410  Black  GND  Ground 
LT-510, LT-511  Shield  Earth  Shield/Earth Ground