MATRIX 400™ REFERENCE MANUAL 
26   
2 
 ID-NET™ M/S Multidata: Multiple stations – single reader 
ID-NET™ interface allows connection of readers reading objects placed on independent 
conveyors. All readers are typically located far away from each other and they use a 
dedicated presence sensor. 
At the end of each reading phase, each reader transmits its own data message to the host. 
Thanks to ID-NET™, data collection among readers is accomplished at a high speed without 
the need of an external multiplexing device. This leads to an overall cost reduction and to a 
simple system wiring. 
A complete ID-NET™ reader network can be easily setup through VisiSet™ as follows: 
Mounting & Connection 
1.  Mechanically mount/install all the readers (refer to par. 3.2 and 3.3). 
2.  Wire ID-NET™ (refer to par. 4.3 or 5.5). 
3.  Power up the entire system. 
Configuration of Slaves 
1.  Connect a PC equipped with VisiSet™ to the Main, Auxiliary or Ethernet interface of the 
planned Slave reader. 
2.  Launch VisiSet™ and connect to the Slave reader. 
3.  From the VisiSet™ Device Menu select "Parameter Setup". 
4. Set the Role of the Slave reader (Synchronized or Multidata) from the 
Reading System Layout > Device Network Setting > Topology Role parameter. 
5. Set the Slave Address according to the desired value 0-31 from the 
Reading System Layout  >  Device Network Setting > Slave Address parameter. Each 
reader must have a different Address on the ID-NET™ Network. 
6. If necessary, set the ID-NET™ baudrate from the Reading System Layout > 
Device Network Setting > Network Baud Rate parameter, (500 kbs default).