REFERENCES

5

 

5.9.3Copy OM-GRYPHON™

Procedure:

Using the slave reader and its OM-GRYPHON™ cradle, read the Restore Default barcode, set the radio address, and then read the RS232 interface barcode from chapter 4 of this manual or from the Quick Reference Manual.

Connect the master OM-GRYPHON™ and the slave OM-GRYPHON™ (cradle to be configured) together through two RS232 serial interface cables and external power supply. Accessory cables and power supply are available from your Datalogic distributor to provide this connection.

RS232 Cables: CAB363 & CAB364 or CAB320 & CAB328

Power Supply: PG12

Read the Configuration Copy barcode below with a reader. Then place it onto the master OM-GRYPHON™ cradle.

Copy Configuration

i ;;k

i ;;k

i ;;k

$+ZZ3$-

The configuration will be copied from the master OM-GRYPHON™ to the slave OM-GRYPHON™. The reader signals the end of the procedure with a series of beeps.

Repeat the procedure above to configure other slave cradles.

Note: The master OM-GRYPHON™ can be configured for any interface.