A |
|
| GRYPHON™ |
|
|
| |
|
|
|
|
|
| DATA FORMAT (continued) |
|
NOT FOR PEN EMULATION INTERFACES |
| ||
DESCRIPTION |
|
| STRING |
Code Length Tx |
| not transmitted | EE0 |
|
| transmitted in | EE1 |
|
| transmitted in fixed | EE2 |
Field Adjustment |
| disable | EF0 |
|
| right addition | EFa0d |
|
| left addition | EFa1d |
|
| right deletion | EFa2d |
|
| left deletion | EFa3d |
Field Adjustment Character |
| EGe | |
Character Replacement |
| disable character replacement | EO0 |
|
| first character replacement | EO1afg |
|
| second character replacement | EO2afg |
|
| third character replacement | EO3afg |
Address Stamping |
| disable reader address stamping | RU0 |
|
| enable reader address stamping | RU1 |
Address Delimiter |
| disable reader address delimiter | RV0 |
|
| enable reader address delimiter and select | RV1h |
|
| character |
|
a = | ASCII character. |
| |
d = | a number from the Hex/Numeric Table |
| |
e, f, g, h = | HEX values representing an ASCII character |
|
a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 46. d = a number in the range
e = Hex value from 00 to FE
f = Hex value of the character to be replaced from 00 to FE g = Hex value of the new character to insert from 00 to FE
FF= replace with no new character (remove character)
h = a HEX value in the range from 00 - FE representing the ASCII character.
POWER SAVE
DESCRIPTION |
| STRING |
| |
Scan Rate | 67 scans per sec. | BT0 |
| |
|
| 135 scans per sec. | BT1 |
|
|
| 270 scans per sec. | BT2 |
|
Sleep State | disable | BQ0 |
| |
|
| enable | BQ1 |
|
Enter Sleep Timeout (100 ms) |
|
| ||
Standby | enable | BM0 |
| |
|
| disable | BM1 |
|
148 |
|
|
|
|
|
|
|
|