Datalogic Scanning 90ACC1780 manual Ink-Spread, Overflow Control, Interdigit Control

Models: 90ACC1780

1 171
Download 171 pages 50.82 Kb
Page 138
Image 138

5

GRYPHON™

 

5.6DECODING PARAMETERS

 

These parameters are intended to enhance the decoding capability

 

of the reader for particular applications. Used incorrectly, they can

 

degrade the reading performance or increase the possibility of a

CAUTION

decoding error.

 

5.6.1Ink-Spread

The ink-spread parameter allows the decoding of codes which are not perfectly printed because the page texture tends to absorb the ink.

5.6.2Overflow Control

The overflow control parameter can be disabled when decoding codes printed on small surfaces, which do not allow the use of an overflow space.

This command does not effect code families 2/5, Code 128 and Code 93.

This command is forced (enabled) when PDF417 codes are enabled.

5.6.3Interdigit Control

The interdigit control parameter verifies the interdigit spacing for code families Code 39 and Codabar.

5.7RADIO PARAMETERS (M SERIES ONLY)

5.7.1Radio Protocol Timeout

This parameter sets the valid time to wait before transmission between the M series reader and OM-GRYPHON™ cradle is considered failed.

This parameter should be set taking into consideration the radio traffic (number of readers in the same area).

If the RS232 interface is used with ACK/NACK enabled, this parameter should be at least equal to the RX Timeout parameter for low traffic environments. It should be increased if there are many readers in the same area.

It can be set between 2 and 19 seconds.

128

Page 138
Image 138
Datalogic Scanning 90ACC1780 manual Ink-Spread, Overflow Control, Interdigit Control, Radio Parameters M Series only