REFERENCES | 5 |
|
5.3.3Address Stamping
It is possible to include the reader address in the message sent to the host. The reader Address Stamping parameter consists of a
For message output format, refer to par. 5.3.
5.3.4Address Delimiter
The Address Delimiter allows a character to be included to separate the reader Address stamping field from the next field in the message. Any character can be included in the hexadecimal range from 00 to FE.
For message output format, refer to par. 5.3.
5.4POWER SAVE
5.4.1Sleep State
This mode allows the ∝ P in the reader to enter a “Sleep” state for minimum power consumption. For
Before entering Sleep mode, the following are verified:
•no commands coming from Host
•no data being transmitted to Host
•Enter Sleep Timeout ended (see par. 5.4.2)
To exit Sleep mode press the trigger.
Enabling the Sleep state implements Standby mode for CCD devices, see par. 5.4.3.
For
5.4.2Enter Sleep Timeout
For readers that have the Sleep state enabled, this timeout determines when the reader will enter this state.