HOST CONFIGURATION STRINGS |
|
| A | ||
|
|
|
|
| |
|
|
|
|
|
|
|
| CODE SELECTION (continued) |
| ||
DESCRIPTION |
|
|
| STRING | |
| ISBN Conversion codes | enable ISBN | AP1 | ||
|
|
|
| enable ISSN | AP2 |
|
|
|
| enable ISBN and ISSN | AP3 |
|
|
|
| disable ISBN and ISSN | AP0 |
Code 39 | disable Code 39 family |
| AB0 | ||
| Standard | no check digit control | AB11 | ||
|
| check digit control and transmission | AB12 | ||
|
| check digit control without transmission | AB13 | ||
| Full ASCII | no check digit control | AB21 | ||
|
| check digit control and transmission | AB22 | ||
|
| check digit control without transmission | AB23 | ||
| CIP 39 |
|
|
| AB3 |
| Code 32 |
|
|
| AB4 |
| code length |
|
|
| AB*xxxx |
2/5 | disable Code 2/5 family |
| AC0 | ||
| Interleaved 2/5 |
| no check digit control | AC11xxxx | |
|
|
| check digit control and transmission | AC12xxxx | |
|
|
| check digit control without transmission | AC13xxxx | |
| Normal 2/5 5 bars | no check digit control | AC21xxxx | ||
|
|
| check digit control and transmission | AC22xxxx | |
|
|
| check digit control without transmission | AC23xxxx | |
| Industrial 2/5 (IATA) | no check digit control | AC31xxxx | ||
|
|
| check digit control and transmission | AC32xxxx | |
|
|
| check digit control without transmission | AC33xxxx | |
| Matrix 2/5 3 bars | no check digit control | AC41xxxx | ||
|
|
| check digit control and transmission | AC42xxxx | |
|
|
| check digit control without transmission | AC43xxxx | |
| CIP/HR |
|
|
| AC5 |
xxxx= ASCII numbers that define the code length where:
•First 2 digits = minimum acceptable code length.
•Second 2 digits = maximum acceptable code length.
The minimum code length must always be less than or equal to the maximum. The maximum code length for all codes is 99 characters:
Examples:
0132 = variable length from 1 to 32 digits in the code. 1010 = 10 digit code length only.