Procedure:

Using the slave reader and its OM-GRYPHON™ cradle, follow the initialization procedure in chapter 4 of this manual or from the Quick Reference Manual.

With the master GRYPHONM (correctly configured reader), read the Copy Configuration barcode below. Then place it onto an OM-GRYPHON™ cradle within 10 seconds. The reader will beep indicating the configuration has been copied.

The configuration will be simultaneously sent over the RS232 interface of the OM-GRYPHON™. If this causes undesired effects disconnect the RS232 cable between the PC and OM-GRYPHON™ during this process.

Copy Configuration

i ;; k

i ;; k

i ;; k

$+ZZ0$-

With the slave GRYPHONM, read the Get Configuration barcode below. Then place it onto the same OM-GRYPHON™ cradle used in the step above. The slave reader's address will not be changed.

Get Configuration

i ;;k

i ;;k

i ;;k

$+ZZ2$-

The configuration will be copied from the master to the slave GRYPHONM. The slave GRYPHONM signals the end of the procedure with a series of beeps. It is now ready to be used with its own OM-GRYPHON™ cradle.

Repeat the procedure above to configure other slave readers. The OM-GRYPHON™ can continue to configure slave readers until it receives another command or data.