TECHNICAL FEATURES | 6 |
|
6.4SYSTEM AND RADIO FEATURES
Radio Features | European Models |
| USA Models |
Working Frequency | 433.92 MHz |
| 910 MHz |
Bit Rate | 19200 |
| 36800 |
Effective Radiated Power | <10 mW |
| <1 mW |
Range (in open air) | 30 m |
| 15 m |
RF Modulation |
| FSK |
System Configurations |
|
| STARGATE™ |
Maximum number of devices per | 16 |
| 255 |
base stations |
| ||
|
|
| |
Maximum number of devices in the |
| 2000 | |
same reading area |
| ||
|
|
| |
Maximum number of base stations |
|
| 16 |
in network |
|
| |
|
|
|
6.5STATUS INDICATORS
The reader has three indicators, LED, Beeper and Good Read Spot. The OM- GRYPHON™ and
|
| H = high tone | L = low tone | ||
GRYPHON™ D/M READER |
| ||||
|
|
|
|
|
|
| Beeper¹ |
| Meaning |
| |
| L L L L |
| Parameters loaded correctly |
| |
|
|
|
|
| |
| H H H H |
| Parameter loading error, reading or writing error in the non volatile | ||
| long tones |
| memory |
| |
|
|
|
|
| |
|
|
|
|
|
|
| H L H L |
| Hardware error in EEPROM |
| |
|
|
|
|
| |
GRYPHON™ D/M READER CONFIGURATION |
| ||||
|
|
|
|
|
|
| Beeper¹ |
|
| Meaning |
|
|
|
|
|
| |
| H H H H |
|
| Correct entry or exit from Configuration mode | |
|
|
|
|
|
|
| L |
|
| Good read of a command |
|
|
|
|
|
|
|
| L L L |
|
| Command read error |
|
|
|
|
|
|
|
139