Data Editing

Label ID: Set Individually Per Symbology

To configure a Label ID individually for a single symbology:

1.Scan the ENTER/EXIT barcode.

2.Select Label ID position as either BEFORE (Enable as Prefix) or AFTER (Enable as suf- fix) by scanning the appropriate barcode in the section Label ID Control on page 100. Reference Figure 6 for Label ID positioning options if multiple identification features are enabled.

3.Scan a barcode to select the symbology for which you wish to configure a custom Label ID from the section Label ID Symbology Selection, starting on page 101.

4.Determine the desired character(s) (you may choose up to three) which will represent the Label ID for the selected symbology.

5.Turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID. For example, if you wish to select an equal sign (=) as a Label ID, the chart indicates its associated hex characters as 3D. Turn to Keypad, starting on page 291 and scan the barcodes representing the hex characters determined. For the example given, the characters ‘3’ and ‘D’ would be scanned. More examples of Label ID settings are provided in Table 18.

If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

NOTE

6.Scan the ENTER/EXIT barcode to exit Label ID entry.

7.Scan the ENTER/EXIT barcode once again to exit Programming Mode.

This completes the steps to configure a Label ID for a given symbology.

Figure 6. Label ID Position Options

Prefix

Label ID

Aim ID

Bar Code Data

Label ID

Suffix

OR

98

QuickScan® QD2100

Page 106
Image 106
Datalogic Scanning QD2100 manual Label ID Set Individually Per Symbology