Symbologies

Standard 2 of 5 — cont.

Standard 2 of 5 Set Length 2

This feature specifies one of the barcode lengths for Standard 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check and data charac- ters.

The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).

Follow these instructions to set this feature:

1.Determine the desired character length (from 1 to 50 — or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

2.Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode.

3.Scan the barcode: SELECT STANDARD 2 OF 5 LENGTH 2 SETTING.

4.Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the length setting which was determined in the steps above. You will hear a two-beep indi- cation after the last character.

If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

NOTE

5.Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure. See Table 34 for some examples of how to set this feature.

Table 34. Standard 2 of 5 Length 2 Setting Examples

STEP

ACTION

 

 

EXAMPLES

 

 

 

 

 

 

 

1

Desired Setting (pad with leading

00 (Ignore This

 

07 Characters

15 Characters

50 Characters

zeroes)

Length)

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Scan ENTER/EXIT PROGRAMMING MODE

 

 

 

 

 

 

 

 

3

Scan SELECT STANDARD 2 OF 5 LENGTH 2 SETTING

 

 

 

 

 

 

 

 

 

 

4

Scan Two Characters From

‘0’ and ‘0’

 

‘0’ and ‘7’

‘1’ and ‘5’

‘5’ AND ‘0’

Appendix E, Keypad

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Scan ENTER/EXIT PROGRAMMING MODE

 

 

 

 

 

 

 

 

 

 

252

QuickScan® QD2100

Page 260
Image 260
Datalogic Scanning QD2100 manual Standard 2 of 5 Length 2 Setting Examples